Plan Review Notes
Plan Review Notes For Permit 03111139
Permit Number 03111139
Review Stop B
Sequence Number 5
Notes
Date Text
2004-06-15 00:00:00ADDITIONAL RATIONAL ANALYSIS REVIEWED.
 REQUIREMENT FOR STRUCTURAL MULLION RED-
 LINED.
2004-05-28 00:00:00BUILDING PLAN REVIEW
 ***REVISION DENIED***
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 REVISION SUBMITTED 5/26/04 PROPOSING
 ALTERNATIVE STOREFRONT AND DOOR PRODUCTS
  
 1) KAWNEER STOREFRONT PRODUCT APPROVAL,
 FL627.DRAWING SHEET 1 OF THE MIAMI-
 DADE PRODUCT APPROVAL NOA #02-0220.01
 SHOWS A MAXIMUM FRAME HEIGHT OF 114"
 WHICH IS LESS THAN THE 131" PROPOSED ON
 THOMAS TWOMEY, P.E. DRAWING SHEET 2.
 SUBMIT A PRODUCT APPROVAL FOR AN
 APPROPRIATE HORIZONTAL MULLION.
  
 2) KAWNEER STOREFRONT PRODUCT APPROVAL,
 FL627.DRAWING SHEET 1 OF THE MIAMI-
 DADE PRODUCT APPROVAL NOA #02-0220.01
 SHOWS A MAXIMUM PANEL WIDTH OF 48" WHICH
 IS LESS THAN THE 55" WIDTH OF WINDOW
 TYPES D AND E PROPOSED ON THOMAS
 TWOMEY, P.E. DRAWING SHEET 2.THAT 48"
 WIDTH COMBINED WITH THE SPECIFIED 96"
 HEIGHT IS ALSO OUTSIDE THE SCOPE OF THE
 SUBMITTED RATIONAL ANALYSIS CALCULATION.
 SUBMIT ALTERNATIVE PRODUCT APPROVAL.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]


Account Summary | Usage Policy | Privacy Policy