| Date |
Text |
| 2004-06-15 00:00:00 | ADDITIONAL RATIONAL ANALYSIS REVIEWED. |
| | REQUIREMENT FOR STRUCTURAL MULLION RED- |
| | LINED. |
| 2004-05-28 00:00:00 | BUILDING PLAN REVIEW |
| | ***REVISION DENIED*** |
| | ROBERT BROWN(561) 805 6716 |
| | E-MAIL: [email protected] |
| | |
| | REVISION SUBMITTED 5/26/04 PROPOSING |
| | ALTERNATIVE STOREFRONT AND DOOR PRODUCTS |
| | |
| | 1) KAWNEER STOREFRONT PRODUCT APPROVAL, |
| | FL627.DRAWING SHEET 1 OF THE MIAMI- |
| | DADE PRODUCT APPROVAL NOA #02-0220.01 |
| | SHOWS A MAXIMUM FRAME HEIGHT OF 114" |
| | WHICH IS LESS THAN THE 131" PROPOSED ON |
| | THOMAS TWOMEY, P.E. DRAWING SHEET 2. |
| | SUBMIT A PRODUCT APPROVAL FOR AN |
| | APPROPRIATE HORIZONTAL MULLION. |
| | |
| | 2) KAWNEER STOREFRONT PRODUCT APPROVAL, |
| | FL627.DRAWING SHEET 1 OF THE MIAMI- |
| | DADE PRODUCT APPROVAL NOA #02-0220.01 |
| | SHOWS A MAXIMUM PANEL WIDTH OF 48" WHICH |
| | IS LESS THAN THE 55" WIDTH OF WINDOW |
| | TYPES D AND E PROPOSED ON THOMAS |
| | TWOMEY, P.E. DRAWING SHEET 2.THAT 48" |
| | WIDTH COMBINED WITH THE SPECIFIED 96" |
| | HEIGHT IS ALSO OUTSIDE THE SCOPE OF THE |
| | SUBMITTED RATIONAL ANALYSIS CALCULATION. |
| | SUBMIT ALTERNATIVE PRODUCT APPROVAL. |
| | |
| | **QUOTE PERMIT# ON ALL CORRESPONDENCE** |
| | |
| | END OF REVIEW COMMENTS |
| | THE CODE REFERENCES GIVE ADDITIONAL INFO |
| | TELEPHONE: (561) 805 6716ROBERT BROWN |
| | E-MAIL: [email protected] |