2003-12-19 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03110910
 ADD: 500 S AUSTRALIAN # 1000
 CONT: HERBERT F. KAHLERT
 TEL: (561)718-5569
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 BUILDING PROVISO:
  
 1) SHEET A-3.0 ALL BACKING IN WALLS TO
 BE FIRE RETARDANT TREATED WOOD.609.2.1
  
 2)704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026