2004-01-10 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHT 4 SANITARY RISER DIAGRAM DOES
 NOT REFLECT THE FLOOR PLAN, NOR DOES IT
 MEET CODE REQUIREMENTS. PLEASE CLAIRFY
 LINE FROM BLDG DRAIN TO BOTTOM OF LAV
 STACK. WHERE DOES BLDG DRAIN GO AFTER
 LAST BATHROOM? TUB NOT VENTED IN FIRST
 BATH. TEE FITTINGS NOT APPROVED BETWEEN
 W/C'S AND TUBS.
 2) THE RISER SHALL REFLECT THE FLOOR
 PLAN. I SUGGEST THE PLUMBING CONTRACTOR
 LAY OUT THE RISER DIAGRAM AS IT WILL BE
 INSTALLED.
  