| 2004-01-13 00:00:00 | DENIED BY ROBIN SINGER - NEED A FULLY |
| | DIMENSIONED SITEPLAN TO COMPLETE REVIEW. |
| | PARKING SPACES, DRIVE ASLES & LANDSCAPE |
| | BUFFERS NOT DIMENSION. |
| | - PARKING SPACES MUST BE DOUBLE STRIPED |
| | DETAIL C4.3 SHOWS SINGLE STRIPING |
| | -FENCE GATE EXCEEDS ALLOWABLE HEIGHT |
| | (72"+10% OF HEIGHT FOR DECOATIVE ELEMENT |
| | -34 PARKING SPACES REQUIRED, 30SHOWN. |
| | PLEASE PROVIDE PARKING CALCUATIONS |
| | -MAIN PEDESTIAN ENTRY MUST FACE THE |
| | SHEET. SUGGEST OPENING UP ENTRY NEXT TO |
| | OFFICE @ TOWER.RAILING SHOWN ON |
| | ELEVATION BUT DOES NOT SHOW UPON SITE OR |
| | FLOORPLAN PLEASE CLARIFY. |
| | -NEED CALCULATIONS FOR % OF OPENINGS IN |
| | FACADE |
| | -PLEASE PROVIDE LANDSCAPE CALCULATIONS. |
| | BASED ON OPEN SPACE & LINEAR BUFFER 101- |
| | 118 TREES.PLANS SHOWS 79 TREES |
| | -BUFFER WALL NEXT TO RESIDENTIAL SHOULD |
| | DROP TO 30", 20FT FRON 49TH & 50TH ST |
| | -VARIANCES TO NUMMERIAL & DIMENSIONAL |
| | REQUIREMENTS ARE POSSIBLE NEED THE |
| | ABOVE INFORMATION TO DETERMINE WHAT |
| | VARIANCE ARE NECESSARY |
| | - MECHANICAL EQUIPMENT MUST BE SCREENED |
| | BACK IS NOT |
| | -8FT SIDEWALK REQ'D ALONG BROADWAY |