Plan Review Notes
Plan Review Notes For Permit 03110456
Permit Number 03110456
Review Stop B
Sequence Number 2
Notes
Date Text
2004-03-05 00:00:00BUILDING REVIEW CHECKLIST:
 1-SITE SPECIFIC PRODUCT APPROVAL FOR
 ROYAL WALL SYSTEM DOESN'T MEET THE
 REQUIREMENTS STIPULATED ON THE FORM:
 A)NEED APPROVED THIRD PARTY QUALITY
 ASSURANCE ENTITY.
 B)EVALUATION REPORT DOCUMENTATION WITH
 INFORMATION REQUIRED BY 9B-72.040(5)
 WAS NOT SUBMITTED.
 C)NEED COMPLETE ENGINEERED WALL PANELS
 PACKAGE FOR THIS SITE SPECIFIC INSTA-
 LLATION.
 D)PROVIDE COMPLETE DETAILS AND SPECS FOR
 WOOD LEDGERS AT SECOND FLOOR. ARCHITEC
 TURAL PLANS SAY TO SEE STRUCTURAL DWGS
 AND STRUCTURAL DWGS SAY CONNECTION BY
 OTHERS. SEC. 104.2.1.2 CITY AMENDMENTS
 TO FBC 2001.
 2-PERMIT ENGINEERING SERVICES COMPANY
 REGISTERED NUMBER SHOWN ON PLANS DOES
 NOT MATCH FLORIDA REGISTERED NUMBER.
 CLARIFY/REVISE AS REQUIRED.
 3-PRODUCT APPROVALS NEED THE FOLLOWING:
 A)ENTRY DOORS: NEED FLORIDA REPORT AND
 DRAWINGS TO MATCH. THERMA-TRU DOORS &
 BENCHMARK DOORS ARE 2 DIFFERENT DOORS.
 PROVIDE DWGS OF DOORS TO BE INSTALLED
 AND MATCHING PRODUCT APPROVAL PACKAGE.
 B)TRUSS CONNECTORS:PROVIDE FLORIDA OR
 LOCAL PRODUCT APPROVAL INFORMATION
 ALONG WITH DADE COUNTY DRAWINGS.
  
 4-PROVIDE INFO. FOR STORM SHUTTERS. NEED
 FLORIDA OR LOCAL PRODUCT APPROVAL AND
 COMPLETE INSTALLATION SCHEDULE, KEY
 PLAN, ETC.
 5-ENGINEERING CALCULATIONS FOR TRUSS
 ANCHORS FASTENER TYPE/NUMBER DIFFERENT
 THAN THOSE PUBLISHED BY MANUFACTURER
 TO HAVE ORIGINAL SEAL, SIGNATURE AND
 DATE AND TO HAVE ALL ENGINEER'S INFO.
 AS REQUIRED BY CHAPTER 471 FL. STATUTE
 WHEN SUBMITTING DOCUMENTS FOR PUBLIC
 RECORDS.
 6-NOTICE OF COMMENCEMENT IS VOID BECAUSE
 CONSTRUCTION DIDN'T STARTED WITHIN 90
 DAYS AFTER RECORDATION.
 7-OWES $18.20 FOR UPDATED VALUATION AND
 RADON FEES.