Plan Review Notes
Plan Review Notes For Permit 03110015
Permit Number 03110015
Review Stop B
Sequence Number 1
Notes
Date Text
2003-12-04 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY COURTHOUSE
 AND A COPY SUBMITTED TO THIS OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2) FBC 13-103.1.1.1THE ARCHITECT SHALL
 ENTER HIS NAME AND LICENSE NUMBER ON
 SHEET TWO OF THE ENERGY CODE COMPLIANCE
 FORM, TO CERTIFY COMPLIANCE.
  
 3) FBC 11-4.15DRINKING FOUNTAIN.
 ADD DETAILS TO SHOW THE CODE REQUIRED
 ACCESSIBLE APPROACH, SPOUT HEIGHT AND
 LEG CLEARANCES FOR THE DRINKING FOUNTAIN
  
 4) INCORPORATE THE NOTES REDLINED ON
 SHEETS A-1 AND A-3.
  
 5) IF NEW PLAN SHEETS ARE REQUIRED, IN
 ORDER TO ADDRESS THE ABOVE COMMENTS, THE
 OLD SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHALL BE INCLUDED WITH THE
 RESUBMITTAL FOR COMPARISON OF REVISIONS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]