| 2003-11-13 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 03110011 |
| | ADD: 2951 ELECTRONIC WAY |
| | CONT: ANDERSON-MOORE |
| | TEL: (561)753-7400 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | FOUNDATION PERMIT |
| | ACTION: DENIED |
| | |
| | 1) PROVIDE 2 CURRENT COPIES OF SIGNED & |
| | SEALED SURVEYS WITH PROPOSED IMPROVEMENT |
| | TO BE COMPLETED. PROVIDE SITE DRAWING |
| | INDICATING THE POSITION OF THE BUILDING. |
| | |
| | 2) WEST PALM BEACH ADMINISTRATIVE CODE |
| | 105.3(4) A SPECIAL ONSITE INSPECTOR |
| | SHALL BE ONSITE AT ALL TIMES THAT WORK |
| | IS IN PROGRESS FOR STRUCTURAL COMPONENTS |
| | FOR BUILDINGS WITH AREA GREATER THAN |
| | 20,000 SQ FT. THEY NEED TO REGISTER WITH |
| | DON NEELY OR HAROLD PISKURA, AT 805-6665 |
| | THE OUTSIDE COORDINATOR. |
| | |
| | 3)FL BLD CODE 104.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED, |
| | A) THE STRUCURAL PLANS SUBMITTED, S-1 |
| | & S-3 DO NOT HAVE A FOOTER & FOUNDATION |
| | SCHEDULE. |
| | B) THE STRUCTURAL PLANS DO NOT INDI- |
| | CATE THE DEPTH THE FOOTER IS BELOW FIN- |
| | ISHED GRADE. ARDAMANS GEOTECHNICAL RE- |
| | PORT REQUIRES A MINIMUM OF 18" BELOW |
| | FINAL GRADE. |
| | C) PLANS INDICATE TOP OF FOUNDATION: |
| | SEE PLAN??????????NOT SHOWN ON S-1/S-3. |
| | |
| | 4) 104.4.5. SPECIAL FOUNDATION PERMIT |
| | WHEN APPLICATION FOR A PERMIT TO ERECT |
| | OR ENLARGE A BUILDING HAS BEEN FILED, & |
| | PENDING ISSURANCE OF SUCH PERMIT, THE |
| | BUILDING OFFICIAL MAY, AT HIS/ HER |
| | DISCRETION, ISSUE A SPECIAL PERMIT FOR |
| | THE FOUNDATION ONLY, UPON WRITTEN RE- |
| | QUEST OF THE OWNER AND CONTRACTOR. THE |
| | HOLDER OF SUCH A SPECIAL PERMIT IS PRO- |
| | CEEDING AT HIS OR HER OWN RISK AND WITH- |
| | OUT ASSURANCE THAT A PERMIT FOR THE |
| | REMAINDER OF THE WORK WILL BE GRANTED |
| | AND THAT CORRECTIONS WILL NOT BE RE- |
| | QUIRED IN ORDER TO MEET THE PROVISIONS |
| | OF THE TECHNICAL CODE. |
| | A) THE CODE ARTICLES IN REGARDS TO THE |
| | HANDICAPPED RAMP, IT CAN NOT BE DETERMIN |
| | ED THAT THE FOUNDATION PERMIT HAS COR- |
| | RECTED THESE ITEMS. |
| | |
| | 5)BEFORE A PERMIT TO CONSTRUCT, MAY |
| | BE ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 6) BEFORE A PERMIT CAN BE ISSUED, STATE |
| | RADON TO BE PAID AT .01 PER SQ. FT.= |
| | $278.38. |
| | |
| | 7) SPECIAL INSPECTOR SUBMIT (3) OF ALL |
| | PLANS, REPORTS, SUBMITTALS. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |