| Plan Review Notes For Permit 03101412 |
| Permit Number |
03101412 |
|
| Review Stop |
ENG |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2003-11-18 00:00:00 | FAILED: | | | 1. SHEET PD 1 OF 4, PLEASE SHOW ALL THE | | | DRAINAGE PIPE, STRUCTURES BEING REMOVED, | | | RELOCATED OR TO BE ABANDONED. REFER TO | | | POST DEVELOPMENT DRANAGE BASIN EXHIBIT 2 | | | ( DB 2) IN DRANAGE REPORT. | | | 2. SHEET PD 4, LAKE 1 CONTROL STRUCTURE | | | DETAILS SHOWS WIER INV. ELEVATION AT | | | 14.35', CALCULATION SHOWS IT AT 10.91' | | | PLEASE VERIFY. | | | 2. PLEASE SHOW DOMESTIC WATER LINE TO | | | THE PROPOSED CLUBHOUSE AND POOL, A | | | SEPARATE BACKFLOW PREVENTER FOR THE | | | POOL IS REQUIRED. | | | 3. PROPOSED WORK IN CONGRESS AVE. AND | | | EXECUTIVE CENTER DR. REQUIRES PERMIT AND | | | APPROVAL FROM COUNTY AND CITY | | | RESPECTIVELY. | | | 4. A COPY OF SFWMD PERMIT IS AT THE TIME | | | OF ACTUAL PERMITING MUST BE SUBMITTED. | | | 5. DRIVEWAY APPROACHES MUST BE | | | CONSTRUCTED WITH 6" CONCRETE FROM EDGES | | | OF PAVEMENT TO PROPERTY LINE. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|