| 2003-11-29 00:00:00 | *****CORRECTIONS****** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 |
| | |
| | 1.)PROVIDE THE RECEIPT FOR IMPACT |
| | FEES. |
| | |
| | 2.)SEE PREVIOUS LIST, ITEM #6, ATTIC |
| | ACCESS REQUIRED.SHEET A2.0 SHOWS AN |
| | EXISTING ATTIC ACCESS SERVING THE |
| | EXISTING HOUSE.IF THE TRUSSES ARE TO |
| | REMAIN, ACCESS TO THE NEW ATTIC AREA |
| | (ADDITION) WILL NOT BE POSSIBLE.PLEASE |
| | CALL ME TO CLARIFY IF NECESSARY. |
| | |
| | 3.)THE PRODUCT APPROVALS SUBMITTED, |
| | KINCO SINGLE HUNG IMPACT WINDOW, ARE |
| | ACCEPTABLE FOR SOME WINDOWS ON THE PLAN |
| | BUT NOT FOR THE LARGER WINDOWS.THE |
| | DESIGN PRESSURE FOR THE WINDOWS EXCEED |
| | THE MAXIMUM DESIGN LOAD CAPACITY (SEE |
| | THE PRODUCT APPROVAL, HIGHLIGHTED). |
| | |
| | 4.)THE THERMA-TRU DOOR HAS A STATUS |
| | OF "PENDING" ON THE DCA WEBSITE.PER |
| | THE FLORIDA BUILDING COMMISSION, WE |
| | CANNOT ACCEPT PRODUCTS ON THE PENDING |
| | LIST.THIS PERMIT CAN BE ISSUED WITH A |
| | PROVISO THAT A SEPARATE PERMIT BE |
| | OBTAINED FOR THE DOOR.THERE AREN'T ANY |
| | EXTERIOR DOORS ON THE PLAN; IF YOU ARE |
| | REPLACING AN EXISTING DOOR AND WISH FOR |
| | IT TO BE COVERED UNDER THIS PERMIT, |
| | REVISE YOUR PERMIT APPLICATION, |
| | INDICATING WHICH DOOR IS BEING REPLACED. |
| | |
| | 5.)THE PLANS SHOW WINDOWS WHICH ARE |
| | "EXISTING", BUT YOUR PERMIT APPLICATION |
| | INDICATES "WINDOW REPLACEMENT".ARE |
| | YOUR REPLACING ALL OF THE WINDOWS IN |
| | THE HOUSE?IF YOU ARE, EXISTING |
| | BEDROOMS WITH WINDOW BEING REPLACED |
| | MUST COMPLY WITH FBC1005.4, EMERGENCY |
| | EGRESS.THE SIZES SHOWN DO NOT COMPLY. |