| Plan Review Notes For Permit 03101244 |
| Permit Number |
03101244 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2003-10-25 00:00:00 | DENIED | | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | | FORMATION REQUIRED FOR PLAN REVIEW | | | 1) FBC-2001 424.2.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. MANUFACTURE | | | SHEETS REQUIRED. (SUBMITTAL) | | | 2) FBC-2001 424.2.14.2 WATER RETENTION, | | | PROVIDE A POSITIVE MEANS OF RETAINING | | | WATER IN THE HEATER WHEN PUMP IS SHUT | | | OFF. (MANUFACTURE CUT SHEETS SUBMITTAL) | | | 3) AN APPROVED MAIN OUTLET, WHEN PROVID- | | | ED, SHALL BE LOCATED ON A WALL OR FLOOR | | | AT OR NEAR THE DEEPEST POINT IN THE POOL | | | FOR EMPTYING OR CIRCULATION, OR BOTH OF | | | THE WATER IN THE POOL. (NO DRAIN SHOWN | | | IN THE POOL)SEC 424.2.21.3 | | | 4) SECTION 424.2.21.4 HYDROSTATIC RELIEF | | | DEVISE. IN AREAS OF ANTICIPATED WATER | | | TABLE AN APPROVED HYDROSTATIC RELIEF DE- | | | VISE SHALL BE INSTALLED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|