Plan Review Notes
Plan Review Notes For Permit 03100781
Permit Number 03100781
Review Stop B
Sequence Number 1
Notes
Date Text
2003-10-30 00:00:00*****CORRECTIONS*****
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 561-805-6724
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.A NOC WAS NOT
 GIVEN TO THE CITY OF WPB WHEN THE DEMO
 PERMIT WAS ISSUED DUE TO THE VALUE
 BEING LESS THAN $2500.
  
 2.)IMPACT PROTECTION REQUIRED, FBC
 1606.1.4.SUBMIT A HURRICANE SHUTTER
 INSTALLATION SCHEDULE, SEE ATTACHED.
  
 3.)SUBMIT TWO COPIES OF PRODUCT
 APPROVALS FOR THE METAL DOOR, WINDOWS,
 IMPACT PROTECTION, ROOF. ANY LEGIBLE,
 CURRENT PRODUCT APPROVALS NOT SUBMITTED
 BEFORE THE PERMIT IS ISSUED WILL NOT
 BE INCLUDED AS PART OF THIS PERMIT AND
 WILL REQUIRE A SEPARATE PERMIT.
  
 4.)THIS IMPROVEMENT IS OVER 50% OF
 VALUE, FBC3401.7.2.6.SOME COMMENTS ON
 THIS LIST ARE AFFECTED BY THIS CODE
 SECTION.
  
 5.)ADDITIONAL PERMITS REQUIRED.
  
 6.)PROVIDE A WALL SECTION FROM
 FOUNDATION THROUGH THE ROOF, FBC104.3.1.
 1., INCLUDING ASSEMBLY AND MATERIALS.
  
 7.)ENERGY CALC REQUIRED, FBC13-101.2.
 "INSULATE" IS A PART OF THE DESCRIPTION
 OF WORK ON THE PERMIT APPLICATION.
 SHOW INSULATION R VALUES ON THE WALL
 SECTION.PLEASE NOTE THAT 600C IS A
 PRESCRIPTIVE METHOD; WALL SECTION MUST
 MEET MINIMUMS ON THE ENERGY CALC.
  
 8.)SIGN THE OWNER/AGENT LINE OF THE
 ENERGY CALC, FBC13-101.2.
  
 9.)PROVIDE A SURVEY OF THIS PROPERTY.
 ALSO PROVIDE A SITE PLAN, SHOWING ALL
 DIMENSIONS TO SCALE.YOU ARE ADDING A
 PORCH; ZONING APPROVAL REQUIRED.
  
 10.) ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA
 SHALL BEAR THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN (EACH
 PAGE) FBC104.2.1.
  
 11.)PROVIDE A HURRICANE SHUTTER
 INSTALLATION SHEDULE, SEE ATTACHED.
  
 12.)THE WINDOW IN THE BATHROOM (ABOVE
 THE TUB) IS TO COMPLY WITH FBC2405.2
 (SAFETY GLASS); SHOW ON PLAN.
  
 13.)SHOW WINDOW TYPE, SIZE AND SILL
 HEIGHT FOR BEDROOM WINDOWS TO COMPLY
 WITH FBC1005.4.
  
 14.)SHOW FRONT DOOR SIZE.THE FRONT
 DOOR IS TO COMPLY WITH TABLE 1004 (32"
 MIN. CLEAR OPENING).
  
 15.) SMOKE DETECTORS REQUIRED FOR
 BEDROOMS, FBC905.2.2.
  
 16.) STAIRS ARE BEING REMOVED, WAS THIS
 TO ACCESS THE ATTIC?THE BUILDING
 APPEARS TO BE A ONE STORY (ELEVATION).
 ATTIC ACCESS REQUIRED, FBC2309.IF YOU
 ARE REPLACING THE STAIRS WITH AN ATTIC
 ACCESS THE SIZE MUST COMPLY WITH
 FBC2309, SHOW SIZE ON FLOOR PLAN.
  
 17.) SPECIFY ALL CONNECTORS; BRAND AND
 MODEL NUMBER WITH MAX UPLIFT.
  
 18.)THE LAMINATED BEAM APPEARS TO BE
 A DOUBLE FROM THE SIDE VIEW, BUT IS
 SPECIFIED AS A SINGLE ON THE FRONT VIEW.
  
 19.)SHOW A FRAMING DETAIL FOR THE ROOF
 OF THE FRONT PORCH.
  
 20.)A LANDING TO COMPLY WITH FBC1007.4
 .2 IS REQUIRED AT THE FRONT DOOR.
  
 21.)PROVIDE A DETAIL OF THE LANDING
 AND STAIRS, WITH DIMENSIONS.THE SIDE
 ELEVATION SHOWS FOUR STEPS, FRONT
 ELEVATION SHOWS THREE.HANDRAIL MAY
 BE REQUIRED FBC1007.5.1.IF A HANDRAIL
 IS REQUIRED, PROVIDE A DETAIL TO COMPLY
 WITH FBC1007, FBC1608.
  
 WHEN RESUBMITTING, CLOUD ALL REVISIONS.
 CHANGE ONLY AFFECTED SHEETS AND SUBMIT
 OLD SHEETS SEPARATELY.