| Date |
Text |
| 2004-03-23 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | [email protected] |
| | |
| | 1.)A NOTICE OF COMMENCEMENT MUST BE |
| | FILED WITH THE CLERK OF COURTS BEFORE A |
| | PERMIT CAN BE ISSUED, FS713.13. |
| | |
| | 2.)SEE THE PREVIOUS LIST.THE SURVEY |
| | SHOWS A SCREEN ENCLOSURE AND AN |
| | EXISTING SLAB.YOU ARE BUILDING THROUGH |
| | HALF OF IT.ARE YOU DEMOLISHING THE |
| | SCREEN ROOM, CONCRETE SLAB?SHOW ON |
| | THE PLAN.(ITEMS #3 AND 8) |
| | |
| | 3.)SEPARATE PERMITS REQUIRED. |
| | |
| | 4.)SEE PREVIOUS LIST, ITEM #6.AREA |
| | CALCULATIONS WERE PROVIDED, AND THE |
| | ADDITION IS AN OVER 25% IMPROVEMENT. |
| | SHOW COMPLIANCE WITH FBC3401.7.2, 2003 |
| | AMENDMENT. |
| | |
| | 5.)THE ENERGY CALC IS MISSING THE |
| | INFORMATION FOR ITEM #8 ON PAGE ONE, |
| | AND IS NOT FILLED OUT ON PAGE TWO. |
| | ALSO SIGN THE OWNER/AGENT LINE.FBC |
| | 13-103.1. |
| | |
| | 6.)SEE THE PREVIOUS LIST, ITEM #19. |
| | THE CONNECTORS SPECIFIED ARE NOT IN |
| | THE USP 2003 CATALOG (EXAMPLE, RTPGA836, |
| | RT24). CHECK ALL CONNECTORS ON THE PLAN. |
| | |
| | 7.)SEE PREVIOUS LIST, ITEM #20.THE |
| | WINDOW/DOOR BUCK DETAIL IS FOR MASONRY, |
| | WALL SECTION IS FRAME. (D1) |
| | |
| | 8.)SEE PREVIOUS LIST, STATEWIDE, LOCAL |
| | OR SITE SPECIFIC PRODUCT APPROVALS |
| | REQUIRED IN ADDITION TO THE TEST |
| | REPORTS.THE TEST REPORT SUBMITTED FOR |
| | THE SHUTTERS WERE ILLEGIBLE.I HAVE |
| | PRINTED NEW TEST REPORTS AS WELL AS |
| | THE FLORIDA STATEWIDE PRODUCT APPROVAL |
| | FOR THE SHUTTERS.PRODUCT APPROVALS |
| | FOR THE SLIDING GLASS DOOR, WINDOW AND |
| | ROOF, AND CONNECTORS ARE REQUIRED. |
| | WWW.FLORIDABUILDING.ORG |
| | |
| | 9.)THE APPROVED ZONING SITE PLAN IS |
| | NOT IN THE PACKAGE.PROVIDE A SITE |
| | PLAN FOR ZONING APPROVAL. |
| | |
| | 10.) THE PRINTED LICENSE NUMBER OF THE |
| | PERSON SEALING THE PLAN IS TO BE ON |
| | EACH SHEET, INCLUDING THE 8 1/2 X 11", |
| | FAC61G15-23.002. |
| | |
| | 11.)ADDITIONAL FEES DUE (VALUE |
| | ADJUSTMENT AND RADON), SEE ATTACHED |
| | BZS 238893 AND 238894.PLEASE RETURN |
| | THE BZ WHICH WAS IN THE PACKAGE |
| | PREVIOUSLY SO THAT IT CAN BE VOIDED. |
| | |
| | 12.)S2 INDICATES THE EXISTING |
| | STRUCTURE AS WOOD FRAME, BUT NOTE #4, |
| | D2 INDICATES CBS WALLS.ALSO IT STATES |
| | "ALL EXISTING"; PLANS SHOW AN |
| | ADDITION. |
| | |
| | 13.)WHEN RESUBMITTING, PLEASE INCLUDE |
| | A TRANSMITTAL SHEET EXPLAINING HOW |
| | EACH ITEM WAS ADDRESSED.REPLACE ONLY |
| | SHEETS WHICH HAVE CHANGED AND SUBMIT |
| | THE OLD SHEETS SEPARATELY. |