| Date |
Text |
| 2004-05-14 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | [email protected] |
| | |
| | 1.)SEE THE SOILS ENGINEER'S |
| | RECOMMENDATIONS IN REGARDS TO FOOTINGS. |
| | ALSO THE SOILS REPORT IS FOR SINGLE |
| | STORY ADDITIONS; REVISE THE SOILS |
| | REPORT TO CORRECTLY REFLECT THE SCOPE |
| | OF WORK.REVISE WALL SECTIONS/FOUND. |
| | PLAN AS NECESSARY. |
| | |
| | 2.)THE NOTICE OF COMMENCEMENT IS FOR |
| | A GARAGE ADDITION.REVISE TO MORE |
| | ACCURATELY REFLECT THE SCOPE OF WORK. |
| | |
| | 3.)PROVIDE A MORE COMPLETE TRAY |
| | CEILING DETAIL.THE FRAMING APPEARS |
| | SUSPENDED; WHERE IS THE OUTSIDE WALL? |
| | IT IS NOT CLEAR HOW THE FIRESTOPS SHOWN |
| | WILL PERFORM AS FIRESTOPS.SEE ATTACHED |
| | AS AN EXAMPLE OF ONE WAY TO SHOW |
| | COMPLIANCE FOR FRAMED WALLS. |
| | |
| | 4.)HANDRAIL REQUIRED AT STAIRS FBC |
| | 1007.5, PROVIDE DETAILS; SHOW COMPLIANCE |
| | WITH FBC CHAPTER 10 AND FBC 1608. |
| | |
| | 5.)THE 7/8 STUCCO (WALL SECTION) IS |
| | TO BE A 3 COAT VERTICAL, NOT A 2 COAT |
| | HORIZONTAL, APPLICATION FBC2504.2.2, |
| | ASTM C926.THIS APPLIES ONLY TO STUCCO |
| | IN A VERTICAL APPLICATION OVER WIRE |
| | LATH. |
| | |
| | 6.)SEE PREVIOUS LISTS, FLORIDA STATE, |
| | LOCAL OR SITE SPECIFIC PRODUCT APPROVALS |
| | REQUIRED IN ADDITION TO THE TEST REPORTS |
| | PROVIDED.WWW.FLORIDABUILDING.ORG |
| | (PRODUCT APPROVAL, SEARCH PRODUCT |
| | APPROVALS). |