| Date |
Text |
| 2003-12-19 00:00:00 | BUILDING PLAN REVIEW |
| | *******DENIED******* |
| | ROBERT BROWN(561) 805 6716 |
| | E-MAIL: [email protected] |
| | |
| | FBC = FLORIDA BUILDING CODE 2001 |
| | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) |
| | |
| | 1) 61G1-16.004FL. ADMIN. CODE.PLANS |
| | PREPARED BY A REGISTERED ARCHITECT SHALL |
| | INCLUDE THE PRINTED NAME OF THE |
| | ARCHITECT SEALING THE PLANS. |
| | |
| | 2) FBC 1005.7.1EGRESS FROM THE |
| | MEZZANINE.THE TRAVEL DISTANCE FROM THE |
| | MOST REMOTE POINT ON THE MEZZANINE TO |
| | THE CLOSEST BUILDING EXIT EXCEEDS 75 FT |
| | (FBC TABLE 1005.7) SO TWO MEANS OF |
| | EGRESS ARE REQUIRED FROM THE MEZZANINE. |
| | AMEND THE PLANS. |
| | |
| | 3) FBC 704.1.4MATERIALS STORAGE ROOM. |
| | ANNOTATE SHEET A-1 TO SPECIFY THE |
| | REQUIRED 2-HOUR FIRE-RATED WALLS AND |
| | CEILING/ROOF TO THIS ROOM. |
| | |
| | 4) FBC 705.1.3SHEET A-7, DETAIL 10. |
| | FIRE DOOR JAMB.WHERE DOES THIS DETAIL |
| | APPLY?IT SPECIFIES A 1-HOUR FIRE-RATED |
| | DOOR FRAME AND 45-MINUTE FIRE-RATED DOOR |
| | WHICH DO NOT CORRELATE WITH ANY DOOR ON |
| | THE DOOR SCHEDULE. |
| | |
| | 5) FBC 1608.2SHEET S-3 AND S-5.AMEND |
| | THE PLANS TO SPECIFY THE CODE |
| | REQUIREMENT FOR THE HANDRAILS AND |
| | GUARDRAIL TO SUPPORT A 200LB |
| | CONCENTRATED LOAD AND 50 PLF LINE LOAD |
| | (APPLIED AS PER THE CODE) ACTING IN ANY |
| | DIRECTION. |
| | |
| | 6) FBC* 1804.2.2AREA OF QUESTIONABLE |
| | SOIL.SUBMIT A GEOTECHNICAL REPORT |
| | TO VERIFY THE SAFE BEARING CAPACITY OF |
| | THE SOIL. |
| | |
| | 7) A SEPARATE PERMIT APPLICATION WILL BE |
| | REQUIRED FOR THE AWNINGS. |
| | |
| | 8) SUBMIT PRODUCT APPROVALS FOR THE |
| | WINDOWS, EXTERIOR DOORS, ROLL-UP DOORS |
| | AND WALL/ROOF PANELS. |
| | NOTE: FL. ADMIN CODE RULE 9B-72 (IN |
| | EFFECT SINCE OCTOBER 1, 2003) REQUIRES |
| | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR |
| | SITE-SPECIFIC PRODUCT APPROVAL.THE |
| | SUBMITTAL SHOULD INCLUDE THE STATEWIDE |
| | PRODUCT APPROVAL NUMBER (FL###), |
| | AVAILABLE FROM THE DEPT OF COMMUNITY |
| | AFFAIRS PRODUCT APPROVAL WEBSITE |
| | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP |
| | |
| | 9) IF NEW PLAN SHEETS ARE REQUIRED, IN |
| | ORDER TO ADDRESS THE ABOVE COMMENTS, THE |
| | OLD SHEETS SHALL BE REMOVED AND THE NEW |
| | SHEETS INSERTED.ONE COPY OF EACH OLD |
| | SHEET SHALL BE INCLUDED WITH THE |
| | RESUBMITTAL FOR COMPARISON OF REVISIONS. |
| | |
| | **QUOTE PERMIT# ON ALL CORRESPONDENCE** |
| | |
| | END OF REVIEW COMMENTS |
| | THE CODE REFERENCES GIVE ADDITIONAL INFO |
| | TELEPHONE: (561) 805 6716ROBERT BROWN |
| | E-MAIL: [email protected] |