| 2003-10-21 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 03100556 |
| | ADD: 1500 CLARE AVE |
| | CONT: O/B IVANCEVIC, DANILO |
| | TEL: (561)493-1975 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | ACTION: DENIED |
| | |
| | 1)TABLE 704.1 OCCUPANCY SEPERATION |
| | REQUIREMENTS; PLEASE INDICATE THE USAGE |
| | OF EACH AREA. WILL THE LARGER AREA BE US |
| | ED FOR INDUSTRIAL, FACTORY OR STORAGE? |
| | IF STORAGE WHAT TYPE OF MATERIALS WILL |
| | BE STORED THERE? |
| | 2) STORAGE INDICATE (2) MEANS OF EGRESS, |
| | MUST BE SWING DOORS, NOT OVERHEAD DOORS? |
| | SEE 1027.1.1. |
| | 3)1004.1.4 WHERE 2 OR MORE EXITS OR |
| | EXIT ACCESS DOORS ARE REQUIED, AT LEAST |
| | 2 OF THE EXIT OR EXIT ACCESS DOORS SHALL |
| | BE PLACED A DISTANCE APART EQUAL TO NOT |
| | LESS THAN 1/2 OF THE LENGTH OF THE MAX- |
| | IMUM OVERALL DIAGONAL DIMENSION OF THE |
| | BUILDING OR AREA TO BE SERVED. |
| | 4) DEPENDING ON THE TYPE OF STORAGE A |
| | OCCUPANCY SEPERATION WALL WILL BE RE- |
| | QUIRED. 1HR VS 2 HR WALL.TABLE 704.1. |
| | 5) THE PROPOSED OFFICE EXSPANSION, IS |
| | STORAGE TO BE CONSIDERED ABOVE THIS NEW |
| | CEILING? |
| | 6) FL BLD CODE 2405.2 HAZARDOUS LOCATION |
| | PROVIDE SAFETY GLASS FOR THIS LOCATION: |
| | 2405.2.1(3) GLAZING IN AN INDIVIDUAL FIX |
| | ED OR OPERABLE PANEL ADJACENT TO A DOOR |
| | WHERE THE NEAREST VERTICAL EDGE IS WITH- |
| | IN A 24" RADIUS OF THE DOOR IN A CLOSED |
| | POSITION. |
| | 7) TABLE 803.3 MINIMUM INTERIOR FINISH |
| | CLASSIFICATION; PROVIDE INFORMATION |
| | BASED ON INTERIOR FINISH REQUIREMENTS |
| | BASED ON OCCUPANCY/ SPRINKLERED VS |
| | NONSPRINKLERED? |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |