| 2003-12-16 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 |
| | |
| | 1.)ADDITIONAL PERMITS REQUIRED. |
| | |
| | 2.)A NOTICE OF COMMENCEMENT MUST BE |
| | FILED WITH THE CLERK OF COURTS BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 3.)SEE PREVIOUS LIST, ITEM #3. PROVIDE |
| | AREA CALCULATIONS ON THE PLAN.EXISTING |
| | WAS NOT PROVIDED.BE SURE THAT THE |
| | AREAS MATCH THE ENERGY CALCS.ADDITIONS |
| | OF OVER 25% ARE TO COMPLY WITH FBC |
| | 3401.7.2, 2003 AMENDMENT. |
| | |
| | 4.)THE DIMENSIONS ON THE PLAN ARE |
| | 24X24, PLANS CALL IT A 441 SF ADDITION, |
| | IMPACT FEE STAMP IS FOR 551 SF.TOTAL |
| | ADDITION AREA IS STILL NOT CLEAR. |
| | |
| | 5.)SEE PREVIOUS LIST, ITEM #4.THE |
| | SURVEY DOES NOT MATCH THE PLAN. |
| | |
| | 6.)SIGN THE OWNER/AGENT LINE OF THE |
| | ENERGY CALC, FBC13-103.1.2. |
| | |
| | 7.)SEE PREVIOUS LIST, ITEM #6.NOTES |
| | IN INK ARE TO BE INITIALED BY THE |
| | ENGINEER. |
| | |
| | 8.)SEE PREVIOUS LIST, ITEM #8, |
| | CITY OF WEST PALM BEACH AMENDMENTS TO |
| | THE FBC1804.1.7, LOWEST BUILDING FLOOR |
| | ELEVATION AT THE PERIMETER OF A |
| | MONOLOTHIC FOUNDATION AT HABITABLE |
| | AREAS SHALL BE A MINIMUM OF 4" ABOVE THE |
| | FINISHED GRADE.SHOW ON WALL SECTION. |
| | |
| | 9.)SEE PREVIOUS LIST, ITEM #11, |
| | ADDITIONAL FEES MAY BE DUE, TO BE |
| | CALCULATED AFTER THE SQUARE FOOTAGE OF |
| | THE ADDITION IS DETERMINED. |
| | |
| | 10.)SEE PREVIOUS LIST, ITEM#14, |
| | A TITLE BLOCK FOR THE ENGINEER IS |
| | REQUIRED, FAC61G15-23.001.SJE DESIGN |
| | & CONSTRUCTION HAS A DELINQUENT |
| | GENERAL CONTRACTOR LICENSE AND |
| | ENGINEERING AUTHORIZATION NUMBER. |
| | BOTH NUMBERS ARE REQUIRED TO BE ON THE |
| | TITLE BLOCK.ADDRESS. |
| | |
| | 11.)SEE PREVIOUS LIST, ITEM #16.A |
| | STATEWIDE OR SITE SPECIFIC PRODUCT |
| | APPROVAL IS REQUIRED IN ADDITION TO |
| | THE DADE COUNTY NOAS PROVIDED; SEE |
| | WWW.FLORIDABUILDING.ORG FOR MORE |
| | INFORMATION. |
| | |
| | 12.)SEE PREVIOUS LIST, ITEM #17, |
| | SHOW COMPLIANCE WITH EGRESS REQUIREMENTS |
| | BY GIVING WINDOW SIZE AND TYPE ON THE |
| | PLAN.A 24X20 OPENING DOES NOT COMPLY. |
| | |
| | 13.)SEE PREVIOUS LIST, ITEMS #18 AND |
| | 21.IF A HURRICANE SHUTTER INSTALLATION |
| | SCHEDULE IS NOT PROVIDED, A SEPARATE |
| | PERMIT WILL BE REQUIRED. |
| | |
| | 14.)SEE ATTACHED NOTICE IN REGARDS TO |
| | FS553.80(2)(B).A 4X FEE WILL BE |
| | CHARGED IF ITEMS ARE NOT ADDRESSED. |