| Plan Review Notes For Permit 03100367 |
| Permit Number |
03100367 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2003-12-08 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLA. ADMIN. CODE | | | FLA. STATUES | | | | | | 1) SANITARY RISER DIAGRAM DOES NOT MEET | | | CODE REQUIREMENTS. WASH MACHINE SHALL | | | NOT DRAIN THROUGH THE WET VENT FOR THE | | | BATHROOM GROUP. 909.1 - CONNECT THE W/M | | | DISCHARGE LINE IN DOWNSTREAM OF THE | | | BATHROOM FIXTURES. CONNECT THE WATER | | | CLOSET LINE INTO THE VENT FOR THE LAV. | | | 2) SIGNATURE REQUIRED ON SEAL OF ENGIN- | | | EER PER FAC 61G15-23.002(1) & FS 471.025 | | | INITIALS ARE NOT ACCEPTABLE PER FBPE & | | | BLDG. OFFICIAL. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|