| Plan Review Notes For Permit 03100126 |
| Permit Number |
03100126 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2003-10-11 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLORIDA ADMIN. CODE | | | | | | 1) SECTION 909.1 LAUNDRY SINK AND WASH | | | MACHINE SHALL CONNECT DOWNSTREAM OF THE | | | BATHROOM GROUP WET VENT. | | | 2) SECTION 802.4 WASH MACHINE REQUIRES | | | A STANDPIPE. | | | 3) SECTION 708.10 CLEANOUT FOR WASH | | | MACHINE SHALL BE 4' ABOVE THE FLOOR FOR | | | ACCESS. | | | 4) SECTION 104.2.1 SANITARY RISER DIA- | | | GRAM DOES NOT REFLECT THE FLOOR PLAN. | | | FLOOR PLAN SHOWS A TUB AND RISER SHOWS | | | A SHOWER. PLEASE CLAIRFY. | | | 5) SEE ATTACHED SHEET ABOUT DESIGN PRO- | | | FESSIONALS. 61G1-16.004(2) LICENSE NUM- | | | BER REQUIRED ON TITLE BLOCK. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|