| Plan Review Notes For Permit 03091654 |
| Permit Number |
03091654 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2004-04-08 00:00:00 | CONTRACTOR BROUGHT BACK PLANS ON 4-8-04. | | 2003-12-31 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-REVISE/UPDATE TRUSS ANCHOR SCHEDULE & | | | DETAILS TO COMPLY WITH SEC. 1609.4.3 | | | FBC 2001, WHICH DOESN'T ALLOW THE | | | STEEL STRESS TO BE INCREASED. USE THE | | | HIGH WIND RESISTANT CONSTRUCTION | | | CATALOGUE BY SIMPSON WHICH IS THE | | | CATALOGUE THAT WAS ALREADY REVISED. | | | **NOTE: PROVIDE ENGINEERING CALCULATIONS | | | FOR VALUES OTHER THAN THOSE PUBLISHED | | | ON CATALOGUE. SECTION 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | 2-REVISE SPECIFICATIONS FOR CEILING | | | INSTALLATION AT PORCHES. SEE ASTM | | | C-1063. NEED FASTENER THAT PENETRATES | | | 1 3/4" INTO WOOD. |
|