| 2003-10-09 00:00:00 | BUILDING PLAN REVIEW |
| | *******DENIED******* |
| | ROBERT BROWN(561) 805 6716 |
| | E-MAIL: [email protected] |
| | |
| | FBC = FLORIDA BUILDING CODE 2001 |
| | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) |
| | |
| | 1) FBC 1027.1STORAGE ROOM EXIT.A |
| | MINIMUM OF TWO EXITS FROM THE STORAGE |
| | ROOM ARE REQUIRED (REF ALSO: 1004.1.2). |
| | AT LEAST TWO OF THE EXITS SHALL BE |
| | SEPARATED BY A DISTANCE EQUAL TO NOT |
| | LESS THAN 1/2 THE DIAGONAL DIMENSION OF |
| | THE ROOM (REF: 1004.1.4). |
| | |
| | 2) FBC 301.3STORAGE.ANNOTATE THE |
| | PLANS TO SPECIFY THE MATERIALS THAT ARE |
| | TO BE STORED.SEE FBC 308 FOR MATERIALS |
| | AND QUANTITIES THAT ARE CLASSIFIED AS |
| | HAZARDOUS OCCUPANCY. |
| | |
| | 3) AMEND SHEET SP-1 AS FOLLOWS: |
| | (A) GENERAL NOTE #3 REFERS TO "....2001 |
| | FLORIDA BUILDING CODE, WITH 2002 |
| | AMENDMENTS."THE REFERENCE SHALL ALSO |
| | INCLUDE THE 2003 AMENDMENTS (EFFECTIVE |
| | JUNE 30, 2003). |
| | (B) THE ABOVE COMMENT ALSO APPLIES TO |
| | THE BUILDING CODE ANALYSIS TABLE.AMEND |
| | THE TABLE. |
| | (C) THE BUILDING CODE ANALYSIS TABLE |
| | STATES "FIRE DISTRICT:N/A".THE |
| | BUILDING WILL BE IN THE FIRE DISTRICT. |
| | AMEND THE TABLE. |
| | |
| | 4) FBC* F102.2.4FIRE DISTRICT. |
| | ROOF COVERING IN THE FIRE DISTRICT SHALL |
| | CONFORM TO THE REQUIREMENTS OF CLASS A |
| | OR CLASS B ROOF COVERINGS AS DEFINED IN |
| | 1505.ANNOTATE THE PLANS TO STATE THE |
| | REQUIRED FIRE CLASSIFICATION FOR THE |
| | ROOF COVERING. |
| | |
| | 5) FBC 1804.1.3 DETAIL 2/S-3. THE BOTTOM |
| | OF FOUNDATIONS SHALL EXTEND NO LESS THAN |
| | 12 INCHES (305 MM) BELOW FINISH GRADE. |
| | ANNOTATE THE PLANS TO SHOW THE REQUIRED |
| | MINIMUM DEPTH. |
| | |
| | 6) FBC* 1804.2.2AREA OF QUESTIONABLE |
| | SOIL.SUBMIT A GEOTECHNICAL REPORT |
| | TO VERIFY THE SAFE BEARING CAPACITY OF |
| | THE SOIL. |
| | |
| | 7) SUBMIT TWO COPIES OF A PRODUCT |
| | APPROVAL FOR THE PROPOSED BUILT UP |
| | ROOFING SYSTEM, OR A SEPARATE ROOFING |
| | PERMIT, AND FEES, WILL BE REQUIRED. |
| | THE PRODUCT APPROVAL SHEETS SHALL BE |
| | MARKED, AS APPROPRIATE TO IDENTIFY WHICH |
| | PRODUCT OPTIONS/MATERIALS ARE TO BE USED |
| | |
| | 8) SUBMIT TWO COPIES OF A PRODUCT |
| | APPROVAL FOR THE PERSONNEL DOORS AND THE |
| | SECTIONAL DOORS. |
| | THE PRODUCT APPROVAL SHEETS SHALL BE |
| | MARKED, AS APPROPRIATE TO IDENTIFY WHICH |
| | PRODUCT OPTIONS/MATERIALS/SIZES ARE TO |
| | BE USED. |
| | |
| | 9) IF NEW PLAN SHEETS ARE REQUIRED, IN |
| | ORDER TO ADDRESS THE ABOVE COMMENTS, THE |
| | OLD SHEETS SHALL BE REMOVED AND THE NEW |
| | SHEETS INSERTED.ONE COPY OF EACH OLD |
| | SHEET SHALL BE INCLUDED WITH THE |
| | RESUBMITTAL FOR COMPARISON OF REVISIONS. |
| | |
| | **QUOTE PERMIT# ON ALL CORRESPONDENCE** |
| | |
| | END OF REVIEW COMMENTS |