2003-10-24 00:00:00 
  
  
  
 PASSED/PROVISO
  
 FIELD INSPECTOR SHALL VERIFY THAT DRYERS
 ARE CSA APPROVED. CHECK TAG ON DRYERS.
  
 REVISION REQUIRED FOR GAS RISER DIAGRAM
 SEE RED LINE CORRECTIONS.
  
 IF GAS LINE IS WELD PIPE, THEN PRIOR TO
 COMMENCING WELDING THE FOLLOWING INFOR-
 MATION IS REQUIRED AT APPLICATION FOR
 THE SEPARATE GAS PERMIT REQUIRED.
 A) CERTIFICATION OF WELDER
 B) PICTURE IDENTIFICATION OF WELDER
 C) COPY OF WELDING PROCEDURE TO BE USED
 ---INSPECTION WILL BE REQUIRED AT TACK-
 UP OF PIPE AND FITTINGS.--INSPECTION
 WILL BE REQUIRED AT ROOT PASS --INSPECT-
 ION WILL BE REQUIRED AT FINAL WHEN GAS
 PIPE IS TESTED FOR ROUGH INSPECTION. ---
  
  
  