| Plan Review Notes For Permit 03081864 |
| Permit Number |
03081864 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2003-10-25 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SANITARY RISER DIAGRAM DO NOT MEET | | | CODE REQUIREMENTS NOR DO THEY REFLECT | | | THE FLOOR PLAN. | | | POWDER ROOM: LAV NOT VENTED. "S" TRAPS | | | NOT APPROVED SECTION 1002.3(5) | | | KITCHEN: ISLAND SINK TO CONNECT ON THE | | | HORIZONTAL BLDG DRAIN. DISHWASHER SHALL | | | CONNECT TO THE TAILPIECE OF THE SINK. | | | BAR SINK: SHALL CONNECT ON THE HORIZONT- | | | AL BLDG. DRAIN AND HAVE A SEPARATE STACK | | | MASTER BATHS: TUB WITH WATER CLOSETS IS | | | NOT VENTED. FIXTURES NOT VENTED ON OTHER | | | STACK, LAVS ARE "S" TRAPPED AND BOTH | | | LAVS ARE NOT ON THE SAME SIDE OF THE | | | WALL. | | | 2) SUBMIT A RISER DIAGRAM SHOWING ALL | | | THE HORIZONTAL BUILDING DRAIN AND SHOW- | | | ING WHERE THE STACKS TIE IN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|