| Date |
Text |
| 2003-09-25 00:00:00 | BUILDING CHECKLIST: |
| | 1-REVISE/UPDATE NOTES ON SHEET SP. NEED |
| | TO REFERENCE UPDATE CODES. SEE PLANS |
| | FOR REDLINED COMMENTS. |
| | 2-DOORS AND WINDOWS CALCULATED DESIGN |
| | PRESSURES ARE NOT LEGIBLE. |
| | 3-PAY IMPACT FEES TO PALM BEACH COUNTY. |
| | BRING BACK STAMPED DRAWINGS AND PAID |
| | RECEIPT. (AFTER DWGS ARE REVISED). |
| | 4-NEED RECORDED NOTICE OF COMMENCEMENT. |
| | 5-REVISE DOOR AND WINDOW BUCK DETAILS. |
| | SEE SECTION 1707.4.4.2 FBC 2001 FOR |
| | PROPER ATTACHMENT. |
| | **ALSO, CLARIFY WHICH DETAILS/SPECS TO |
| | BE USED. THOSE ON SHEET A-5 OR S-2? |
| | 6-SPECIFY WINDOW SIZE FOR OFFICE/GUEST |
| | BEDROOM TO VERIFY FOR EGRESS SIZES |
| | REQUIRED BY SEC. 1005.4 FBC 2001. |
| | **NOTE: KEEP IN MIND THAT CASEMENT WIND. |
| | NEED CENTER MULLION, THEREFORE IT WILL |
| | REDUCE THE CLEAR WIDTH. |
| | 7-PROVIDE 2 COPIES OF PRODUCT APPROVAL: |
| | A)METAL ROOF SYSTEM. (PRODUCT APPROVAL |
| | SUBMITTED IS FOR SHINGLES). |
| | B)FLAT ROOF SYSTEM. |
| | C)FRENCH DOOR TO MATCH GARAGE DOOR. |
| | D)GARAGE DOOR. |
| | E)CASEMENT WINDOWS WITH LEGIBLE DWGS. |
| | F)FRENCH DOORS WITH LEGIBLE DRAWINGS. |
| | |
| | 8-PROVIDE ATTIC ACCESS AT GARAGE WING. |
| | SEC. 2309.6 FBC 2001. |
| | 9-PROVIDE COMPLETE SECTION/DETAIL AND |
| | FASTENER SPECS FOR TRELLIS. SECTION |
| | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| | 10-PROVIDE ROOF FRAMING PLAN SPECIFYING |
| | CALCULATED UPLIFT LOADS AND KEYING |
| | TRUSS ANCHOR SCHEDULE. SECTION 1606 |
| | FBC 2001 AND 104.2.1.2 CITY AMENDMENTS |
| | **ALSO, SHOW ALL BEAMS. EG: FRONT PORCH. |
| | 11-PROVIDE COMPLETE DETAIL/SPECS FOR |
| | CEILING INSTALLATION AT FRONT PORCH |
| | AND SOFFITS. |
| | SEE ASTM C-926 AND ASTM C-1063. |
| | SECTION 2504.2 FBC 2001. |
| | 12-PROVIDE COMPLETE INFORMATION AT ENTRY |
| | STOOP SECTION. SPECIFY STRUCTURAL |
| | MEMBERS AND FASTENERS. SEC. 104.2.1.2 |
| | CITY AMENDMENTS TO FBC 2001. |
| | 13-SEE COMMENTS ON SHEET A-5 NOTES AND |
| | REVISE AS REQUIRED. PLEASE RETURN THE |
| | REVIEWED SET OF DRAWINGS TO EXPEDITE |
| | THE REVIEW PROCESS. |
| | 14-PROVIDE GENERAL SPECIFICATIONS FOR |
| | FIREBLOCKING AT ALL CONCEALED SPACES. |
| | SEE SECTION 2305 FBC 2001. |
| | 15-UPDATE TRUSS ANCHOR SCHEDULE TO |
| | COMPLY WITH SEC. 1609.4.3 FBC 2001, |
| | WHICH DOESN'T ALLOW THE STEEL STRESS |
| | TO BE INCREASED. |
| | **NOTE: IF USING SIMPSON CONNECTORS, |
| | THEN, USE HIGH WIND-RESISTANT CONST. |
| | CATALOGUE WHICH WAS UPDATED TO COMPLY |
| | WITH THIS SECTION OF THE CODE. |
| | 16-CLARIFY WHAT WINDOW/DOOR BUCK DETAIL |
| | SPECS ARE TO BE USED. THOSE SHOWN ON |
| | SHEET A-5 OR S-2?. |
| | 17-UPDATE NOTES ON SHEET A-1. SEE |
| | REDLINED COMMENTS. |
| | 18-CLARIFY ROOF SHEATHING NOTES. THERE |
| | ARE DIFFERENT SPECS THROUGHOUT DWGS. |
| | SEE DWGS A-2, A-3, A-4 AND S-2. |
| | 19-UPDATE/REVISE INFORMATION ON SHEET |
| | S-2. SEE COMMENTS AND RETURN OLD SET |
| | AFTER CORECTIONS ARE DONE TO THE |
| | ORIGINAL CAD DRAWINGS TO EXPEDITE THE |
| | REVIEW PROCESS. |
| | 20-PROVIDE COMPLETE SPECS FOR ENTRY |
| | PORCH. SEE COMMENTS ON SHEET S-1. |
| | 21-ARCHITECT TO HAVE ALL HIS INFORMATION |
| | ON LOGO AS REQUIRED BY CHAPTER 481 |
| | FLORIDA STATUTES. |