| 2003-09-04 00:00:00 | DENIED |
| | |
| | 1) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | |
| | 2) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 3) SUBMIT A SIGNED AND SEALED COPY OF |
| | THE SOIL BORING TEST REPORT AS REQUIRED |
| | BY FBC 1804.2.2. |
| | |
| | 4) THE WALLS OF THE BREAKFAST ROOM AND |
| | THE FAMILY ROOM AT THE RIGHT ELEVATION |
| | APPEAR TO EXCEED THE PERCENTAGE OF WALL |
| | AREA THAT IS ALLOWED AS OPENINGS BY FBC |
| | TABLE 600. THE WALL 18.34' FROM THE |
| | PROPERTY LINE IS ALLOWED 40% OF THE WALL |
| | AREA AS OPENINGS AND THE FAMILY ROOM |
| | WALL AT 26.67' FROM THE PROPERTY LINE IS |
| | ALLOWED 60%. SUBMIT THE TABLE 600 |
| | CALCULATIONS FOR THESE ELEVATIONS. |
| | |
| | 5) THE 16' X 7' OVERHEAD GARAGE DOOR IS |
| | NOT LISTED ON THE WIND LOAD SCHEDULE ON |
| | A1. |
| | |
| | 6) THE SITE SPECIFIC ENGINEERING FOR THE |
| | OUTSWING GLAZED DOOR DOES NOT MEET THE |
| | -60.4 PSF WIND LOAD PRESSURE REQUIRED BY |
| | THE WIND LOAD SCHEDULE ON SHEET A1. |
| | THE SITE SPECIFIC FORM IS NOT SIGNED BY |
| | THE DESIGNER OF RECORD. |
| | |
| | 7) SUBMIT A SIGNED AND SEALED LETTER |
| | FROM THE STORM PANEL ENGINEER STATING |
| | THAT CALK-IN ANCHORS CAN BE USED IN THE |
| | CONCRETE BLOCK. SPECIFY THE PSI OF THE |
| | BLOCK TO ACHIEVE THE PRESSURES AND |
| | SPACINGS INDICATED. |
| | |
| | 8)PROVIDE (2) CURRENT AND COMPLETE |
| | COPIES OF SBCCI OR METRO-DADE PRODUCT |
| | APPROVALS FOR THE ROOFING MATERIAL. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |