| 2003-09-23 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHT P0.1 DOMESTIC WATER ISOMETRIC, | | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" | | | NOT IN THE CEILING AS SHOWN. PDI-WH 201 | | | AND MANUF. INSTALL. INSTRUCT. (SEE NOTE | | | #13 OF THE PLUMING NOTES). | | | 2) SUBMIT PRODUCT APPROVAL SHEETS FOR | | | TOTO FIXTURES, DRINKING FOUNTAIN, AND | | | LAUNDRY TUB. | | | 3) 11-4.1.3(10)(A) PROVISIONS FOR THOSE | | | WHO HAVE DIFFICULTY BENDING OR STOOPING | | | AT DRINKING FOUNTAIN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|