Plan Review Notes
Plan Review Notes For Permit 03080883
Permit Number 03080883
Review Stop P
Sequence Number 1
Notes
Date Text
2003-09-03 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FLORIDA ADMINISTRATIVE CODE
  
 1) SHT A-7 SANITARY RISER DIAGRAM DOES
 NOT REFLECT THE FLOOR PLAN, NOR DOES IT
 MEET CODE REQUIREMENTS.
 A) WASH MACHINE NOT VENTED, REQUIRES A
 STANDPIPE, & REQUIRES A CLEANOUT LOCATED
 4' ABOVE THE FLOOR. SECTIONS 708.10,
 802.4, & 901.2.1.
 B) BATH #3 2ND FLOOR SHOWS A TUB ON THE
 FLOOR PLAN BUT HAS A SHOWER ON THE RISER
 DIAGRAM. LAV SHOWN AS CONNECTING BELOW
 THE FLOOR ON THE RISER AND TUB (SHR) NOT
 VENTED. SECTION 104.2.1
 C) BATH #2 SHOWN AS CONNECTING TO BLDG.
 DRAIN UNDER THE SLAB ON RISER, BUT ITS
 ON THE SECOND FLOOR ON FLOOR PLAN.
 SECTION 104.2.1
 3) LICENSE NUMBER REQUIRED ON EACH SHEET
 PER 61G1-16.004 (TITLE BLOCK)
  
 REVIEW BY KEN STEVENS