| 2003-12-17 00:00:00 | *****CORRECTIONS****** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | [email protected] |
| | |
| | 1.)SEPARATE PERMITS REQUIRED. |
| | |
| | 2.)ADDITIONAL FEES DUE, $43.06, |
| | BZ WAS IN PACKAGE BUT IS NOW GONE. |
| | |
| | 3.)A NOTICE OF COMMENCMENT MUST BE |
| | FILED WITH THE CLERK OF COURTS BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 4.)SEE PREVIOUS LISTS, 3RD TIME ON |
| | THIS CORRECTION, PROVIDE WIND |
| | INFORMATION ON THE PLAN FBC1606.1.7 |
| | INCLUDING COMPONENTS AND CLADDING |
| | (DESIGN PRESSURE FOR DOORS). |
| | |
| | 5.)SEE PREVIOUS LISTS, 3RD TIME ON |
| | THIS CORRECTION, MTSM16 NAILING |
| | CONFLICTS WITH CATALOG.ADDRESS. |
| | |
| | 6.)SEE PREVIOUS LISTS, 3RD TIME, |
| | REGARDING PLYWOOD SOFFIT AND CEILING, |
| | FBC2303.3. |
| | |
| | 7.)SEE PREVIOUS LISTS IN REGARDS |
| | TO LSTA18, NAILING CONFLICTS WITH |
| | CATALOG.3RD TIME |
| | |
| | 8.)THE ROOM DESIGNATION FOR EXISTING |
| | ROOMS WAS REMOVED ON THE NEW DRAWING. |
| | THE ROOM LEADING FROM THE HOUSE TO THE |
| | STORAGE MUST BE SHOWN ON THE PLAN. |
| | |
| | 9.)THE SITE PLAN WHICH WAS NOT ON THE |
| | PLAN PREVIOUSLY BUT IS NOW ON THE NEW |
| | DRAWINGS CONFLICTS WITH THE APPROVED |
| | ZONING.THE ADDITION IS NOW SHOWN ON |
| | THE OTHER SIDE OF THE BUILDING.ISN'T |
| | THIS ALREADY BUILT AND CLEARLY SHOWN ON |
| | THE SURVEY?CLARIFY. |
| | |
| | 10.)SEE THE FIRST LIST IN REGARDS |
| | TO STUCCO, VERTICAL APPLICATION OVER |
| | WIRE LATH IS TO BE 3 COAT 7/8" |
| | FBC2504.2.2.SECOND CORRECTION. |
| | |
| | 11.)SEE THE PREVIOUS TWO LISTS. APPLY |
| | FOR AN A/C PERMIT. |
| | |
| | 12.)AS PER FS553, A 4X PLAN REVIEW IS |
| | BEING CHARGED.SEE ATTACHED.THIS WILL |
| | BE CHARGED EVERY TIME THIS IS |
| | RESUBMITTED AND THE CORRECTIONS HAVE NOT |
| | BEEN MADE. |