| Date |
Text |
| 2003-09-05 00:00:00 | CHECKLIST: |
| | 1-PROVIDE PRODUCT APPROVAL FOR: |
| | A)ENTRY DOOR WITH SIDELITE SINGLE |
| | ASSEMBLY AS SHOWN ON PLANS. |
| | B)OVERHEAD GARAGE DOORS. |
| | C)EXTERIOR SWING DOOR AT GARAGE. |
| | D)SINGLE HUNG WINDOWS. |
| | E)WINDOW MULLIONS. |
| | F)SLIDING GLASS DOORS. |
| | G)FIXED WINDOWS. SEE PLANS FOR SIZES. |
| | H)ARCHED WINDOWS. SEE PLANS. |
| | I)ROOF TILE. |
| | |
| | 2-PROVIDE COMPLETE INFORMATION FOR STORM |
| | SHUTTERS OR APPLY FOR SEPARATE PERMIT. |
| | 3-NEED TWO COPIES OF ENERGY CALCULATIONS |
| | WITH ENGINEER'S ORIGINAL SIGNATURE, |
| | SEAL, DATE, ETC, AS REQUIRED BY |
| | CHAPTER 471 FLORIDA STATUTES. |
| | 4-NEED COMPLETE SOIL TEST REPORT THAT |
| | INCLUDES FOOTING RECOMMENDATIONS AND |
| | SOIL BEARING CAPACITY. SECTION |
| | 1804.2.2 CITY AMENDMENTS TO FBC 2001. |
| | 5-NEED RECORDED NOTICE OF COMMENCEMENT. |
| | 6-SHEET A-1: A)REVISE DETAIL #38. |
| | FOOTING TO BE 12" MINIMUM BELOW GRADE. |
| | SEC. 1804.1.3 FBC 2001. |
| | **INDICATE 4" MINIMUM FINISH FLOOR |
| | ELEVATION ABOVE GRADE. SECTION |
| | 1804.1.7 CITY AMENDMENTS TO FBC 2001. |
| | 7-THERE ARE TWO #A1 DRAWINGS AND DRAWING |
| | A3 IS NOT NUMBERED. REVISE AS REQUIRED |
| | 8-CLARIFY BEAMS SPECIFIED FOR COVERED |
| | PORCH. SEE DETAILS ON SHEET A-6 AND |
| | CLARIFY AS REQUIRED. |
| | 9-SHEET A-4:REVISE BUCK DETAILS TO |
| | COMPLY WITH SECTION 1717.4.4.2 FBC/01 |
| | 10-SPECIFY ANCHOR EMBEDMENT AND WASHER |
| | SIZE REQUIRED FOR GARAGE DOOR |
| | STRUCTURAL BUCK DETAILS. SECTION |
| | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| | 11-SHEET A-5: A)ALL GABLE END DETAILS TO |
| | MATCH ACTUAL CONDITIONS SHOWN ON THE |
| | REAR ELEVATION AND PLANS. REVISE AS |
| | REQUIRED. |
| | B)CLARIFY HOW ARE GABLE END DETAILS |
| | DESIGN TO PROVIDE CONTINUOUS LATERAL |
| | SUPPORT AS REQUIRED BY SEC. 2117 AND |
| | 2313.4 FBC 2001. |
| | C)THERE ARE SOME AREAS THAT HAVE NO |
| | CONNECTORS SPECIFIED. SPECIFY THEM |
| | AS REQUIRED. |
| | D)DETAIL 5/A6 DOESN'T APPLY TO ACTUAL |
| | CONDITIONS SHOWN ON PLAN. REVISE/ |
| | CLARIFY AS REQUIRED. SEC. 104.2.1.2 |
| | CITY AMENDMENTS TO FBC 2001. |
| | 12-PROVIDE GENERAL SPECIFICATIONS FOR |
| | FIREBLOCKING AT ALL CONCEALED SPACES. |
| | SEE SEC. 2305 FBC 2001. |
| | 13-PROVIDE NAILING DIAPHRAGM SHOWING THE |
| | NAILING ZONES. SEE SECTION 2306 CITY |
| | AMENDMENTS TO FBC 2001. |
| | 14-CLARIFY OWNERSHIP OF THIS PROPERTY. |
| | OWNER INFORMATION ON APPLICATION DOES |
| | NOT MATCH INFORMATION ON COMPUTER. |
| | REVISE AS REQUIRED. |