| 2003-08-16 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SANITARY RISER DIAGRAM DOES NOT MEET | | | CODE REQUIREMENTS NOR DOES IT REFLECT | | | THE FLOOR PLAN. | | | A) BATHROOMS AND SINKS ARE NOT VENTED | | | PROPERLY. 1002.3(5) | | | B) WATER CLOSETS SHALL NOT BE DOUBLE | | | TRAPPED. TRAP IS IN FIXTURE. 1002.1 | | | C) SINKS ARE NOT SHOWN ON FLOOR PLAN. | | | D) FLOOR PLAN ON THE DEMO PLAN INDICAT- | | | ES ONE FLOOR. RISER DIAGRAM INDICATES | | | TWO FLOORS. PLEASE CLAIRFY. | | | E) TUB ARE NOT VENTED. 901.2.1 | | | 2) SUBMIT A NEW FLOOR PLAN FOR COMPARI- | | | SON. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|