| Date |
Text |
| 2003-08-18 00:00:00 | *****CORRECTIONS***** |
| | |
| | 1.)SEPARATE PERMITS REQUIRED. |
| | |
| | 2.)ADDITIONAL FEES DUE (RADON), $4.50. |
| | |
| | 3.)THE SITE PLAN (AS1) SHOWS 450 |
| | SF OF ADDITION; AREA CALCULATIONS SHOW |
| | 256 (A1).REVISE; SHOW EXISTING, |
| | PROPOSED, NEW TOTAL. |
| | |
| | 4.)A NOTICE OF COMMENCEMENT MUST BE |
| | FILED WITH THE CLERK OF COURTS BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 5.)IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY BEFORE A PERMIT CAN BE |
| | ISSUED.THE PLANS MUST BE STAMPED AND |
| | THE RECEIPT ATTACHED TO THE APPLICATION. |
| | 233-5025 |
| | |
| | 6.)ENERGY CALCS REQUIRED FBC13-101.5.5 |
| | |
| | 7.)PROVIDE THE ARCHITECT FIRM LICENSE |
| | NUMBER ON THE TITLE BLOCK, FAC61G1- |
| | 16.004(2). |
| | |
| | 8.)FOR ALL ATTACHMENTS, SPECIFY THE |
| | ATTACHMENT WITH UPLIFT. |
| | |
| | 9.)FIRESTOP REQUIRED IN ALL WALLS |
| | AND PARTITION WALLS, FBC705.3. |
| | |
| | 10.) CITY OF WEST PALM BEACH AMENDMENTS |
| | TO THE FBC1804.1.7, LOWEST FLOOR |
| | ELEVATION SHALL BE A MINIMUM OF 4" |
| | ABOVE FINISH GRADE AT THE BUILDING |
| | PERIMETER. |
| | |
| | 11.) BOTTOM OF FOOTER TO BE MINIMUM OF |
| | 12" BELOW FINISH GRADE, FBC1804.1.3. |
| | |
| | 12.) STAIRS SHALL HAVE FLOORS OR |
| | LANDINGS AT DOOR OPENINGS, FBC1007.4.2. |
| | |
| | 13.) THE SUM OF TWO RISERS AND A TREAD |
| | IS REQUIRED TO BE NOT LESS THAN 24", |
| | FBC1007.3. |
| | |
| | 14.)IMPACT PROTECTION REQUIRED FOR |
| | GLAZING (GLAZED DOOR), FBC1606.1.4. |
| | PROVIDE TWO COPIES OF PRODUCT APPROVALS |
| | FOR SHUTTERS. |
| | |
| | 15.) PROVIDE TWO COPIES OF MULLION |
| | PRODUCT APPROVALS. |
| | |
| | 16.) PROVIDE WIND DESIGN INFORMATION, |
| | FBC1606.1.7. |
| | |
| | 17.) PROVIDE A SOILS INVESTIGATION |
| | REPORT. |
| | |
| | SAMANTHA THYNG, BUILDING PLANS EXAMINER |
| | [email protected] |