| Plan Review Notes For Permit 03080127 |
| Permit Number |
03080127 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2003-10-07 00:00:00 | *****PROVISO***** | | | | | | 1.) 30PSF BOTTOM CHORD LIVE LOAD FOR | | | ATTICS W/STORAGE, 10PSF NO STORAGE | | | FBC TABLE 1604.1. | | | 2.) FIREBLOCK FOR STAIRS FBC2305.1.4. | | | (DETAIL 3-7.1), REVISE. | | | 3.) FIRESTOP 2ND FLOOR WALL SECTION 7.1 | | | FBC705.3., REVISE GUARDRAIL/HANDRAIL | | | LANGUAGE TO COMPLY FBC1608.2, SUBMIT | | | REVISION. | | | 4.) REVISE SHEET 3.1 TO SHOW DRAFTSTOP | | | FBC705.3. | | | 5.) SEPARATE PERMIT REQUIRED FOR | | | HURRICANE SHUTTERS; SUBMIT ATTACHMENT | | | SCHEDULE AND PRODUCT APPROVALS. | | | 6.) DETAIL A-2.1, 4" MIN ABOVE GRADE | | | FLOOR ELEVATION, WPB AMEND FBC1804.1.7. | | | SUBMIT REVISION. |
|