| Date |
Text |
| 2003-08-15 00:00:00 | BUILDING PLAN REVIEW |
| | *******DENIED******* |
| | ROBERT BROWN(561) 805 6716 |
| | E-MAIL: [email protected] |
| | |
| | FBC = FLORIDA BUILDING CODE 2001 |
| | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) |
| | |
| | 1) THE NOTICE OF COMMENCEMENT SHALL BE |
| | RECORDED AT PALM BEACH COUNTY COURTHOUSE |
| | AND A COPY SUBMITTED TO THIS OFFICE |
| | BEFORE A PERMIT CAN BE ISSUED.BLANK |
| | FORMS ARE AVAILABLE FROM THIS OFFICE. |
| | |
| | 2) 61G1-16.004 FL. ADMIN. CODE.THE |
| | TITLE ON THE DRAWING SHALL INCLUDE THE |
| | FIRM LICENSE NUMBER (SEE FAC EXTRACT |
| | ATTACHED TO THE ELECTRICAL REVIEW |
| | COMMENT SHEET) |
| | |
| | 3) FBC 11-4.13.6MANEUVERING CLEARANCE |
| | AT THE NEW DOOR TO THE EXISTING LUNCH |
| | ROOM.18" CLEARANCE IS REQUIRED BETWEEN |
| | THE LEADING EDGE OF THE DOOR AND THE |
| | ADJACENT PERPENDICULAR WALL ON THE PULL |
| | SIDE OF THE DOOR.AMEND/ANNOTATE THE |
| | PLANS TO DEMONSTRATE COMPLIANCE.THE |
| | STATEMENT IN NOTE 4 (SHEET A-1) HAS |
| | BEEN NOTED. |
| | |
| | **QUOTE PERMIT# ON ALL CORRESPONDENCE** |
| | |
| | END OF REVIEW COMMENTS |
| | THE CODE REFERENCES GIVE ADDITIONAL INFO |
| | TELEPHONE: (561) 805 6716ROBERT BROWN |
| | E-MAIL: [email protected] |