| 2003-08-18 00:00:00 | DENIED |
| | |
| | 1) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 2) INDICATE HOW ACCESS TO ATTIC WILL BE |
| | PROVIDED AS REQUIRED BY FBC 2309.6. |
| | |
| | 3) FBC 1707.4.4.2 REQUIRES THAT THE 1X |
| | BUCK EXTEND PAST THE INTERIOR FACE OF |
| | THE FRAME TO PROVIDE FULL SUPPORT.PLEASE |
| | REVISE WINDOW BUCK DETAIL A ON A2. |
| | |
| | 4) FBC 1609.4.3 NO LONGER ALLOWS THE |
| | ONE-THIRD INCREASE IN THE STEEL |
| | CALCULATIONS. PLEASE REVISE THE TRUSS |
| | ANCHOR SCHEDULE ON A3 TO VALUES THAT DO |
| | NOT INCLUDE THIS INCREASE. SEE THE 2003 |
| | "USP" CATALOG. |
| | |
| | 5) THE POSITIVE AND NEGATIVE WINDLOAD |
| | PRESSURES ARE NOT SPECIFIED ON THE PLAN |
| | FOR THE BRKFST ROOM WINDOWS AND THE |
| | SLIDING GLASS DOOR IN THE FAMILY ROOM. |
| | |
| | 6) PROVIDE A LINTEL SCHEDULE. |
| | |
| | 7) THE GLASS BLOCK AT THE MASTER BATH |
| | TUB IS IN A HAZARDOUS LOCATION AND IS |
| | REQUIRED TO HAVE A MINIMUM UNIFORM FACE |
| | THICKNESS ON 0.25" PER FBC 2405.2.2. |
| | PLEASE SPECIFY THIS ON PLANS. |
| | |
| | 8) THE OWNER/AGENT IS REQUIRED TO SIGN |
| | THE ENERGY CALC. FORM. FBC 13-103 |
| | |
| | 9) THE PRODUCT APPROVAL FOR THE SLIDING |
| | GLASS DOOR IS FOR THE OXXO CONFIGURATION |
| | ONLY AND DOES NOT COVER THE TWO PANEL |
| | DOOR SHOWN ON THE PLANS. PLEASE SUBMIT |
| | THE APPROPRIATE PRODUCT APPROVAL. |
| | |
| | 10) PLEASE SUBMIT LEGIBLE COPIES OF THE |
| | PRODUCT APPROVALS FOR THE GLASS BLOCK. |
| | |
| | 11) PLEASE SUBMIT MANUFACTURER'S SPECS. |
| | AND UL LISTING INFORMATION FOR THE GAS |
| | BBQ. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |