| Date |
Text |
| 2003-08-18 00:00:00 | DENIED |
| | REFERENCE: FBC-2001 PLUMBING |
| | FBC-2001 CHAPTER 11 |
| | FHA-98 DESIGN MANUAL |
| | |
| | 1) SHTS A05/07/09 SUBMIT CALCULATIOS FOR |
| | PRIMARY AND SECONDARY ROOF DRAINS. SHOW |
| | SQUARE FOOTAGE OF ROOF & SHOW 1/2 AREA |
| | OF VERTICAL WALLS (PARAPETS) IN CALCUL- |
| | ATIONS. SHOW SIZE OF ALL DOWNSPOUTS. |
| | SHOW LOCATIONS FOR ALL SECONDARY ROOF |
| | DRAINS (SCUPPERS) - PROVIDE A DETAIL FOR |
| | ALL DRAINS. SHOW HEIGHT & WIDTH. |
| | 2) SHT P01 OF 29 - S/4 & S/5, SHOW ALL |
| | PIPE SIZES ON ISOMETRIC DIAGRAMS. STAND- |
| | PIPE REQUIRED FOR WASH MACHINE. SECTION |
| | 802.4. - CLEANOUTS REQUIRED 4' ABOVE |
| | FLOOR AT WASH MACHINE. SECTION 708.10 |
| | 3) SHT P01 OF 29 FLOOR PLAN FOR A101/S3 |
| | SECOND FLOOR STACK NOT SHOWN. |
| | 4) SHT P01 OF 29 FLOOR PLAN FOR A102/S4 |
| | SHOWS PIPE RUNNING WEST OF SHOWER AT 2" |
| | THEN 1-1/2" AND TERMINATES IN LAUNDRY |
| | ROOM BY UNIT A103. PLEASE CLAIRFY. ALSO |
| | FLOOR PLAN DOES NOT SHOW WHERE IT TIES |
| | INTO SEWER. |
| | 5) SHT P02 BY 29 ISOMETRIC RISER S/3 |
| | 2ND FLOOR BATHROOM SHALL TIE IN DOWN- |
| | STREAM OF 1ST FLOOR W/C. |
| | 6) SHT P02 OF 29 ISOMETRIC RISER DOES |
| | NOT REFLECT FLOOR PLAN. SEE COMMENT #4. |
| | 7) GAS PERMIT APPLICATION REQUIREMENTS. |
| | SEPARATE GAS PERMIT REQUIRED. |
| | A. SUBMIT AN ISOMETRIC DRAWING THAT |
| | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE |
| | AND CORRESPONDING LENGTHS PER FBC-2001 |
| | FUEL GAS CODE. |
| | B. SHOW TYPE OF PIPING MATERIAL BEING |
| | INSTALLED, ALL PIPE SIZES, (AND THE EDH |
| | NUMBER OF CORRUGATED STAINLESS STEEL |
| | TUBING FOR EACH PIPE SIZE BEING USED. |
| | (GAS NOTES STATES POLYETHYLENE PIPE TO |
| | BE USED ABOVE GROUND. NOT APPROVED PER |
| | SECTION 403.3. DELETE REFERENCE). |
| | C. TYPE OF GAS, (LP OR NATURAL) |
| | D. BTU LOAD OF EACH APPLIANCE AND THE |
| | TOTAL BTU LOAD ON THE SYSTEM. REFER TO |
| | THE FBC-2001 FUEL GAS CODE SECS. 401.8 |
| | THRU 402.5.2 AND TABLES 402(1) THRU |
| | 402(34). |
| | E. SHOW THE DISTANCE FROM THE POINT OF |
| | DELIVERY, (METER), TO THE MOST REMOTE |
| | OUTLET IN THE BUILDING AND/OR SYSTEM PER |
| | FBC-2001 FUEL GAS CODE APPENDIX A - USE |
| | OF CAPACITY TABLES (A)(3). |
| | F. SUBMIT CALCULATIONS FOR COMBUSTION |
| | AIR (IF APPLICABLE) PER FBC-2001 FUEL |
| | GAS CODE SECTION 304. |
| | G. INDICATE THE DELIVERY PRESSURE (PSI) |
| | PER FBC-2001 FUEL GAS CODE SEC. 402.2. |
| | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. |
| | H. SUBMIT A DETAIL SHOWING THE TYPE, |
| | LOCATION, SIZE AND TERMINATION OF THE |
| | GAS VENTS PER FBC-2001 FUEL GAS CODE |
| | SECS. 502 THRU 506. |
| | (IF LP GAS FOLLOWING INFO REQUIRED) |
| | I. CLEARLY SHOW THE LOCATION AND CAP- |
| | ACITY OF LP TANK(S), TYPE OF TANK (DOT |
| | OR ASME), THE DISTANCE OF THE TANK FROM |
| | THE BUILDING AND ADJACENT PROPERTY LINES |
| | THE DISTANCE OF THE TANK FROM ALL SOUR- |
| | CES OF IGNITION, OTHER CONTAINERS, BUILD |
| | INGS, AND THE LOCATION OF ANY BUILDING |
| | OPENINGS BELOW THE RELIEF VALVE OF THE |
| | TANK PER NFPA 58, TABLE 3-2.2.2. |
| | J. CLEARLY INDICATE ON THE PLAN IF THE |
| | LP TANK IS ABOVE OR BELOW GROUND, AND |
| | SHOW REQUIRED PROTECTION OF THE TANK AND |
| | APPURTENANCES PER NFPA 58. IF THE TANK |
| | IS BELOW GROUND THE CONTAINER SHALL BE |
| | SECURILY ANCHORED PER NFPA 58 SECTION |
| | 3-2.2.7(H). |
| | 8) SHT P02 OF 29 PLUMBING NOTES #8, |
| | TABLE 704.1 - PIPE SIZE 2-1/2" OR LESS |
| | SHALL BE RUN AT 1/4" PER FOOT SLOPE MIN. |
| | 9) SHT P02 OF 29 PLUMBING NOTES #29. |
| | AIR CHAMBERS ARE NOT APPROVED. DELETE |
| | FROM REFERENCE. |
| | 10) SHT A04 OF 29 UNITS A101 & A102 |
| | SHALL COMPLY WITH FHA-98 AMENDED DESIGN |
| | MANUAL, REQUIREMENTS 1 THRU 7. DETAILS |
| | SHALL BE SUBMITTED. SHOW ALL BACKING PER |
| | REQ #6. SPECIFICATION "A" OR "B" BATH- |
| | ROOMS PER REQ. #7B, SHOW CLEAR FLOOR |
| | SPACE FOR ALL BATHROOM FIXTURES. SHOW |
| | OPENINGS FOR TOILETS, HEIGHT FOR LAVS. |
| | ECT. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 653-2692 |
| | E-MAIL [email protected] |