| 2003-08-07 00:00:00 | ******CORRECTIONS****** |
| | |
| | 1.)THERE ARE HOLDS ON THIS PROPERTY, |
| | SEE ATTACHED. |
| | |
| | 2.)THE POOL IS TO BE PERMITTED |
| | SEPARATELY.REMOVE FROM THE PERMIT |
| | APPLICATION. |
| | |
| | 3.)SEPARATE PERMITS REQUIRED. |
| | |
| | 4.)THE SITE PLAN SHOWS "ONE STORY |
| | RESIDENCE"; SHOULD SHOW EXISTING AND |
| | PROPOSED. |
| | |
| | 5.)IS THE PRIVACY WALL A PART OF THIS |
| | PERMIT?IF IT IS, IINDICATE AS PROPOSED |
| | AND INCLUDE ON THE FOUNDATION PLAN.THE |
| | FOOTER CANNOT ENCROACH THE PROPERTY |
| | LINE.INCLUDE A DETAIL FOR THE WALL. |
| | IS THE NEW CONCRETE DRIVE A PART OF THIS |
| | PERMIT?INCLUDE ON THE APPLICATION. |
| | |
| | 6.) PROVIDE AREA CALCULATIONS ON THE |
| | PLAN; INCLUDE EXISTING AND PROPOSED. |
| | ADDITIONS OVER 25% MUST COMPLY WITH |
| | FBC3401.7.1.2.1 AS AMENDED 7/1/03. |
| | |
| | 7.) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY.THE PLANS MUST BE |
| | STAMPED, AND THE ORIGINAL RECEIPT |
| | ATTACHED TO THE APPLICATION.233-5025 |
| | |
| | 8.)ENERGY CALCS REQUIRED FBC13-103.1.2 |
| | SIGN THE OWNER/AGENT LINE AS WELL AS |
| | THE PREPARER LINE OF THE ENERGY CALC. |
| | |
| | 9.)ADDITIONAL FEES ARE REQUIRED DUE |
| | TO VALUE ADJUSTMENT.ADDITIONAL FEES |
| | MAY BE ADDED AFTER THE SCOPE OF WORK |
| | IS DETERMINED.ADJUSTMENT WAS MADE FOR |
| | THE ADDITION ONLY; NO INTERIOR |
| | RENOVATIONS, DRIVEWAY, OR ENTRY WALL |
| | AND GATES.PROVIDE AN ESTIMATED VALUE |
| | FOR THESE ITEMS, PROVIDING CONTRACTS IF |
| | AVAILABLE. |
| | |
| | 10.) WILL THE EXISTING FOOTER AND TIE |
| | BEAM TIE INTO THE EXISTING?IF NOT, |
| | NOTE ON THE PLAN. |
| | |
| | 11.) SUBMIT TWO COPIES OF PRODUCT |
| | APPROVALS FOR THE FOLLOWING: |
| | ROOF TILE (MAY BE SUBMITTED WITH THE |
| | ROOF PERMIT APPLICATION) |
| | SINGLE HUNG WINDOW |
| | IMPACT PROTECTION FBC1606.1.4 |
| | FRENCH DOORS |
| | |
| | 12.) IF THE ROOF TILE IS FOAM SET (1-A1) |
| | PROVIDE PRODUCT APPROVALS FOR THE |
| | POLY FOAM. |
| | |
| | 13.) CRAWL SPACE SHALL HAVE CROSS |
| | VENTILATION; SIZE TO CONFORM TO FBC |
| | 1804.6.3. |
| | |
| | 14.) WOOD FLOOR JOISTS TO BE OF |
| | NATURALLY DURABLE WOOD OR PRESSURE |
| | TREATED, FBC2304.3.4. |
| | |
| | 15.) CHANGES DRAWN ON THE PLAN BY THE |
| | DESIGNER SHOULD BE INITIALED AND DATED. |
| | |
| | 16.) SPECIFY A GIRDER CONNECTION ON |
| | THE ROOF FRAMING PLAN. |
| | |
| | 17.) TRUSS ENGINEERING IS FOR 110 MPH |
| | WIND, SBCCI 97.THIS IS AN INCORRECT |
| | WIND AND CODE DESIGNATION, FBC FIGURE |
| | 1606. |
| | |
| | 18.) PROVIDE A SOILS INVESTIGATION |
| | REPORT. |
| | |
| | 19.) THIS PROPERTY IS IN A FLOOD ZONE. |
| | THE LOWEST FLOOR IS TO BE ELEVATED TO |
| | A MINIMUM OF 6" ABOVE THE BASE FLOOD |
| | ELEVATION; INDICATE ON THE PLAN, CITY |
| | OF WEST PALM BEACH MUNICIPAL CODE. |
| | |
| | 20.) SUBMIT A HURRICANE SHUTTER |
| | ATTACHMENT SCHEDULE, SEE ATTACHED. |
| | |