Plan Review Notes
Plan Review Notes For Permit 03070787
Permit Number 03070787
Review Stop B
Sequence Number 1
Notes
Date Text
2003-08-07 00:00:00DENIED
  
 1)FBC 1005.4.5 (GLITCH AMENDMENTS
 JULY 1, 2003) REQUIRES AT LEAST ONE
 MEANS OF ESCAPE FROM A DWELLING WHEN
 SHUTTERED FOR IMPACT PROTECTION. THE
 MEANS OF ESCAPE SHALL BE WITHIN THE
 FIRST FLOOR OF THE DWELLING AND CAN NOT
 BE LOCATED IN A GARAGE. OCCUPANTS IN ANY
 PART OF THE DWELLING SHALL HAVE ACCESS
 TO IT WITHOUT HAVING TO PASS THROUGH A
 LOCKABLE DOOR NOT UNDER THEIR CONTROL.
 INDICATE HOW COMPLIANCE WILL BE
 ACHIEVED.
  
 2) FBC 1909.3 REQUIRES THE WWM IS THE
 SLAB TO BE SUPPORTED ON APPROVED
 MATERIALS AT NO MORE THAN 3 FEET OC.
 PLEASE INDICATE ON PLANS.
  
 3) SPECIFY ON THE FLOOR PLAN THAT GLASS
 BLOCK AT ZERO LOT LINE IS REQUIRED TO
 BE ONE HOUR FIRE RATED.
  
 4) THE GLASS BLOCK AT THE MASTER BATH
 TUB IS IN A HAZARDOUS LOCATION AND IS
 REQUIRED TO HAVE A MINIMUM UNIFORM FACE
 THICKNESS OF 0.25" PER 2405.2. PLEASE
 SPECIFY ON THE PLANS.
  
 5) THE DOOR IN THE GARAGE WALL ADJACENT
 TO THE CONDITIONED SPACE IS REQUIRED TO
 BE SOLID CORE OR INSULATED PER FBC
 CHAPTER 13.
  
 6) SHEET 2 OF THE PLANS LIST THE A/C
 AREA AS 2590 SQFT AND THE ENERGY CALCS.
 HAS 2579 SQFT. PLEASE CORRECT.
  
 7) THE WINDOWS IN THE DEN EXCEED THE 20
 PERCENT OF WALL AREA ALLOWED AS OPENINGS
 BY FBC TABLE 600. (21 SQFT ALLOWED)
  
 8) THE LETTER FROM THE ENGINEER FOR THE
 GLASS BLOCK IS REQUIRED TO BE SIGNED AND
 SEALED WHEN SUBMITTED FOR PUBLIC RECORD
 PER FAC 61G15-23.002.
  
 9) FBC 1609.4.3 DOES NOT ALLOW THE ONE-
 THIRD INCREASE ON THE STEEL CALCULATIONS
 FOR CONNECTORS. PLEASE REVISE THE
 CONNECTOR SCHEDULE ON SHEET 6 TO VALUES
 WHICH DO NOT INCLUDE THIS INCREASE. SEE
 THE 2003 USP AND 2002 SIMPSON HIGH WIND
 RESISTANT CONSTRUCTION CATALOGS.
  
 10) HUGHES WAS PURCHASED BY USP SOME
 TIME AGO. PLEASE UPDATE THE HUGHES
 CONNECTORS SPECIFIED ON SHEET 6 AND IN
 THE DETAILS ON SHEET 8, TO A CURRENT
 MANUFACTURER.
  
 11) PLEASE REVISE THE BUILDING CATEGORY
 ON SHEET 6 TO CATEGORY II. SEE TABLE 1-1
 IN ASCE 7-98. R3 IS THE OCCUPANCY
 CLASSIFICATION.
  
 12) NOTE 10 ON SHEET 8 REFERENCES THE
 WRONG CODE. PLEASE UPDATE TO 2001 FBC.
  
 13) PROVIDE A DETAIL FOR STRUCTURAL 2X
 BUCKS AS REQUIRED BY THE PRODUCT
 APPROVAL FOR THE ENTRY DOOR.
  
 14)FBC 1005.4.5 (GLITCH AMENDMENTS
 JULY 1, 2003) REQUIRES AT LEAST ONE
 MEANS OF ESCAPE FROM A DWELLING WHEN
 SHUTTERED FOR IMPACT PROTECTION. THE
 MEANS OF ESCAPE SHALL BE WITHIN THE
 FIRST FLOOR OF THE DWELLING AND CAN NOT
 BE LOCATED IN A GARAGE. OCCUPANTS IN ANY
 PART OF THE DWELLING SHALL HAVE ACCESS
 TO IT WITHOUT HAVING TO PASS THROUGH A
 LOCKABLE DOOR NOT UNDER THEIR CONTROL.
 INDICATE HOW COMPLIANCE WILL BE
 ACHIEVED.
  
 15) THERE ARE TWO ARCHITECT'S TITLE
 BLOCKS ON THE PLAN. PLEASE REMOVE THE
 ONE THAT DOES NOT BELONG TO THE DESIGNER
 OF RECORD.
  
 16) STORM PANELS: THE SAFEGUARD COMPANY
 IS NO LONGER IN BUSINESS AND WEATHER-
 GUARD HAS NOT COMPLETED THE PROCESS OF
 ASSUMING THE PRODUCT APPROVAL FROM SBCCI
 THE BUILDING OFFICIAL HAS DETERMINED
 THAT WE CAN NOT ACCEPT THIS PRODUCT FOR
 INSTALLATION IN THE CITY OF WPB AT THIS
 TIME.
  
 17) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - GLASS BLOCK
  
 18) THE TRUSS DRAWINGS AND LAYOUT FOR
 SINGLE FAMILY DWELLINGS ARE NO LONGER
 REQUIRED TO BE SUBMITTED FOR PLAN REVIEW
 THEY ARE TO BE GIVEN TO THE INSPECTOR IN
 THE FIELD AT THE TRUSS INSPECTION.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714