| Date |
Text |
| 2003-07-28 00:00:00 | ******CORRECTIONS****** |
| | |
| | SAMANTHA THYNG, BUILDING PLANS EXAMINER |
| | [email protected] |
| | |
| | 1.)TWO COPIES OF ALL PERMITTING |
| | DOCUMENTS MUST BE SUBMITTED.ONLY |
| | ONE SUBMITTED (SURVEY, PRODUCT |
| | APPROVALS). |
| | |
| | 2.)PROVIDE AREA CALCULATIONS ON THE |
| | PLAN - EXISTING AND PROPOSED. |
| | |
| | 3.)A NOTICE OF COMMENCEMENT MUST BE |
| | FILED WITH THE CLERK OF COURTS BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 4.)ENERGY CALCS REQUIRED FBC13-101.2. |
| | |
| | 5.)IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY.THE PLANS MUST BE |
| | STAMPED AND THE ORIGINAL RECEIPT |
| | ATTACHED TO THE APPLICATION.233-5025 |
| | |
| | 6.)ADDITIONAL FEES DUE (VALUE |
| | ADJUSTMENT), $238.97. |
| | |
| | 7.)PROVIDE DESIGN INFORMATION ON THE |
| | PLAN, FBC1606.1.7. |
| | |
| | 8.)SPECIFY DESIGN UPLIFT ON THE PLAN. |
| | |
| | 9.)1 1/2" WATERSTOP REQUIRED, CITY OF |
| | WEST PALM BEACH AMENDMENTS TO THE FBC, |
| | 2111.1.9. |
| | |
| | 10.) THE FOOTER IS TO BE A MINIMUM OF |
| | 12" BELOW GRADE, 1804.1.3. |
| | |
| | 11.) SUBMIT TWO LEGIBLE COPIES OF |
| | THE FOLLOWING PRODUCT APPROVALS: |
| | SINGLE HUNG WINDOW |
| | IMPACT PROTECTION PER FBC1606.1.4 |
| | EXTERIOR DOOR |
| | |
| | 12.) THE SIMPSON CATALOG SPECIFIES THE |
| | LTS AS A CONNECTOR BETWEEN TWO WOOD |
| | MEMBERS.YOU HAVE IT TAPCONNED INTO |
| | A CONCRETE BEAM.CLARIFY. |
| | |
| | 13.)FIRESTOP REQUIRED FBC705.3. |
| | |
| | 14.)PROVIDE A SOILS INVESTIGATION |
| | REPORT. |