Plan Review Notes
Plan Review Notes For Permit 03070374
Permit Number 03070374
Review Stop B
Sequence Number 2
Notes
Date Text
2003-09-23 00:00:00DENIED
  
 1) THE ENGINEER'S NAME, ADDRESS AND
 LICENSE NUMBER IS REQUIRED ON THE PLANS
 AND IF PRACTICING THROUGH AN AUTHORIZED
 BUSINESS THE BUSINESS NAME AND LICENSE
 NUMBER IS REQUIRED PER FAC 61G15-23.002.
 THE ROOF FRAMING PLAN AND ROYALL WALL
 DRAWINGS ARE MISSING THIS INFORMATION.
  
 2) THE ROOF FRAMING PLAN AND ROYALL WALL
 DRAWINGS HAVE NOT BEEN SEALED BY THE
 ENGINEER.
  
 3) THE MANUFACTURER'S SPECS. AND LISTING
 INFORMATION IS REQUIRED IF INSTALLING
 THE OPTIONAL PREFAB FIREPLACE. IF NOT
 BEING INSTALLED CROSS IT OFF ON THE
 PLANS.
  
 4) SUBMIT STRUCTURAL DRAWINGS FOR THE
 CHIMNEY. INDICATE FRAMING, STRAPPING,
 EXTERIOR COVERING, DIMENSIONS, ETC.
  
 5) SEMCO AND HUGHES ARE NO LONGER IN
 BUSINESS. UPDATE SHEETS 6 , RF-1 AND THE
 ROYALL WALL DRAWINGS TO CONNECTORS THAT
 ARE LISTED IN THE CURRENT USP, SIMPSON,
 ETC. CATALOGS.
  
 6)FBC 1005.4.5 (GLITCH AMENDMENTS
 JULY 1, 2003) REQUIRES AT LEAST ONE
 MEANS OF ESCAPE FROM A DWELLING WHEN
 SHUTTERED FOR IMPACT PROTECTION. THE
 MEANS OF ESCAPE SHALL BE WITHIN THE
 FIRST FLOOR OF THE DWELLING AND CAN NOT
 BE LOCATED IN A GARAGE. OCCUPANTS IN ANY
 PART OF THE DWELLING SHALL HAVE ACCESS
 TO IT WITHOUT HAVING TO PASS THROUGH A
 LOCKABLE DOOR NOT UNDER THEIR CONTROL.
 INDICATE HOW COMPLIANCE WILL BE
 ACHIEVED.
  
 7) THE STORM PANEL INFORMATION THAT WAS
 SUBMITTED IS NOT ACCEPTABLE. THE SBCCI
 REPORT FROM AMERICAN ALUMINUM IS NO
 LONGER LISTED. SAFEGUARD IS NO LONGER IN
 BUSINESS AND WEATHERGUARD HAS NOT YET
 HAD SAFEGUARD'S REPORT TRANSFERED TO
 THEM BY SBCCI.
  
 8) THE PRODUCT APPROVAL FOR THE MULLIONS
 DOES NOT APPEAR TO WORK FOR THE 12 FT. X
 10 FT.2 IN. FIXED GLASS WINDOW WITH
 ARCHED F.G. ABOVE LOCATED IN THE GRAND
 ROOM. INDICATE THE LOCATIONS AND SIZES
 OF THE MULLIONS FOR THIS WINDOW.
  
 9) THE TRUSS LAYOUT AND DRAWINGS ARE NOT
 REQUIRED TO BE SUBMITTED FOR PLAN REVIEW
 THE SIGNED AND SEALED SET IS REQUIRED TO
 BE GIVEN TO THE BUILDING INSPECTOR AT
 THE ROOF FRAMING INSPECTION.
  
 IF YOU HAVE QUESTIONS CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714