2003-07-31 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FLORIDA STATUTES
  
 1) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN OR MEET CODE RE-
 QUIREMENTS. THE OPTIONAL LAUNDRY TRAY IN
 THE LAUNDRY ROOM IS NOT SHOWN ON RISER.
 2) THE OPTIONAL LAUNDRY TRAY IN THE
 GARAGE SHALL NOT DRAIN THROUGH THE
 HORIZONTAL WET VENT FOR GUEST BATH #3.
 909.1
 3) SEE ATTACHED SHEET CONCERNING THE
 ARCHITECT'S TITLE BLOCK. NO ARCHITECT
 NUMBER SHOWN.
  