| Plan Review Notes For Permit 03070057 |
| Permit Number |
03070057 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2003-08-20 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03070057 | | | ADD:8049 CRANE'S POINT | | | CONT: NORTHSTAR | | | TEL: (561)662-7700 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | ACTION: DENIED | | | | | | 1) WALL OPENING PRESSURE CHART FOR | | | LOT# 35 NOT FOR LOT# 37. | | | | | | 2) PROVIDE THE SIGNED /SEALED CALS FOR | | | THE BUTT GLASS. | | | | | | 3)1609.4.3 LOAD REDUCTION. | | | WHEN STRUCTURAL EFFECTS DUE TO TWO OR | | | MORE LOADS IN COMBINATION WITH DEAD LOAD | | | ARE INVESTIGATED IN LOAD COMBINATIONS OF | | | 1609.4.1 OR 1609.4.2, THE COMBINED | | | EFFECTS DUE TO THE TWO OR LOADS MULTI- | | | PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD | | | LOADS SHALL NOT BE LESS THAN THE EFFECTS | | | FROM THE LOAD COMBINATION OF THE DEAD | | | LOAD PLUS THE LOAD PRODUCING THE LARGEST | | | EFFECTS. INCREAS IN ALLOWABLE STRESS SPE | | | CIFIED IN THE MATERIALS SECTIONS OF THIS | | | CODE OR A REFRENCED STANDARD SHALL NOT | | | BE USED WITH THESE LOAD COMBINATIONS | | | EXCEPT THAT A DURATION OF LOAD INCREASE | | | SHALL BE PERMITTED IN ACCORDANCE WITH | | | CHAPTER 23. | | | | | | RE-EVALUATE TRUSS ANCHOR SCHEDULE. | | | THE ANCHOR SCHEDULE ITSELF NEEDS TO BE | | | RE-EVALUATED PLUS REASSIGNING WHAT MARK | | | WILL BE USED PER STRAP | | | | | | 4) ADD REVISIONS TO REVISION COLUMN, | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|