| 2003-10-07 00:00:00 | *****CORRECTIONS***** |
| | |
| | SAMANTHA THYNG, BUILDING PLANS EXAMINER |
| | [email protected] |
| | |
| | 1.)SEPARATE PERMITS REQUIRED. |
| | |
| | 2.)A NOTICE OF COMMENCEMENT MUST BE |
| | FILED WITH THE CLERK OF COURTS BEFORE |
| | A PERMIT CAN BE ISSUED. |
| | |
| | 3.)SEE ATTACHED NOTICE REGARDING |
| | FS553.80(2)(B).SEE PREVIOUS CORRECTION |
| | LIST #6 - "EXISTING MASTER BEDROOM AND |
| | BEDROOM ARE REQUIRED TO HAVE EMERGENCY |
| | EGRESS.SPECIFY THE TYPE OF WINDOW, |
| | SHOWING COMPLIANCE WITH FBC1005.4." |
| | THE CORRECTION ON THE PLAN, A-03, WAS |
| | "PROVIDE NEW EGRESS WINDOW IN EXISTING |
| | M.O." WITH AN OPENING SIZE OF 37X51. |
| | PRODUCT APPROVALS FOR AWNING WINDOWS |
| | WERE SUBMITTED.AWNING WINDOWS DO NOT |
| | MEET EMERGENCY EGRESS REQUIREMENTS. |
| | SINGLE HUNG WINDOWS IN THIS SIZE (SEE |
| | ATTACHED) ALSO DO NOT MEET EMERGENCY |
| | EGRESS REQUIREMENTS.PLEASE ADDRESS. |
| | |
| | 4.)THE "NEW GIRDER TRUSS ABOVE DEN" |
| | (A03) ATTACHES TO A BEAM ABOVE A WINDOW. |
| | IS THIS CORRECT? |
| | |
| | 5.)THE WINDOW AT THE SHOWER, BATH 2, |
| | MUST COMPLY WITH FBC2405.1.SHOW ON THE |
| | FLOOR PLAN (A03). |
| | |
| | 6.)S-02, LIVE LOAD FOR THE BOTTOM |
| | CHORD OF THE TRUSSES, ATTIC W/STORAGE |
| | SPACE SHOULD BE 30PSF, FBC TABLE 1604.1. |
| | |
| | 7.)THE PRODUCT APPROVALS FOR THE |
| | LOUVERED VENT IS EXPIRED. |
| | |
| | 8.)NOTE THAT ON PAGE A04 OF THE PLAN, |
| | A DESIGN PRESSURE OF +46/-62 IS |
| | REQUIRED FOR DOORS AND WINDOWS.THE |
| | MAX PRESSURES FOR THE FOLLOWING PRODUCTS |
| | DO NOT MEET THE DESIGN PRESSURE |
| | REQUIREMENTS AS PER THE PRODUCT |
| | APPROVALS: |
| | AWNING WINDOWS |
| | GARAGE DOOR (+44/-56) |
| | MULLIONS (FOR 96X90, +/-35 - FR DOORS) |
| | NOTE - MULLIONS OK FOR WINDOWS |
| | |
| | NOTE - THE IMPACT PRODUCT APPROVALS |
| | FOR THE FRENCH DOORS WERE FOR IMPACT |
| | DOORS W/SIDELITES.IT APPEARS FROM THE |
| | PRODUCT APPROVALS THAT YOU ARE |
| | INSTALLING IMPACT AT THE MASTER BEDROOM, |
| | NON-IMPACT FRENCH DOORS W/MULLIONS AND |
| | SHUTTERS AT THE DINING ROOM (NO SIDELITE |
| | SHOWN ON THE FRENCH DOORS AT THAT |
| | LOCATION). |
| | |
| | 9.)PROVIDE A HURRICANE SHUTTER |
| | ATTACHMENT SCHEDULE, SEE ATTACHED |
| | POLICY. |
| | |
| | 10.) IF ANY PRODUCT APPROVALS ARE NOT |
| | APPROVED AT THE TIME OF ISSUANCE WILL |
| | REQUIRE THAT A SEPARATE PERMIT BE |
| | APPLIED FOR, WITH ADDITIONAL FEES, FOR |
| | THOSE ITEMS. |
| | |
| | PRODUCT APPROVALS MAY BE AVAILABLE AT |
| | WWW.MIAMIDADE.GOV (FIND A DEPT, BUILDING |
| | CODE COMPLIANCE, PRODUCT CONTROL, |
| | SEARCH APPROVED PRODUCTS). |