| Date |
Text |
| 2003-06-16 00:00:00 | PLAN REVIEW NOT A PERMIT APPLICATION. |
| | |
| | THIS WILL BE A THRESHOLD BUILDING AS |
| | DEFINED IN FBC 105.13 AND WILL REQUIRE |
| | A THRESHOLD INSPECTOR AND A THRESHOLD |
| | INSPECTION PLAN PRIOR TO PERMITTING. |
| | |
| | SHEET LS-1 DECLARES A NET ASSEMBLY AREA |
| | OF 10200 SQUARE FEET.THE |
| | LOUNGE/RECEPTIONAREA SHOULD BE |
| | INCLUDED, TOO. |
| | |
| | SHEET LS-1 DECLARES FBC TABLE 600 AS NOT |
| | APPLICABLE TO THE WEST PROPERTY LINE. |
| | THAT IS A COMMON PROPERTY LINE AND TABLE |
| | 600 IS APPLICABLE.THE OPENINGS SHOWN |
| | ON SHEET A4.1 ARE NOT ALLOWED BY FBC |
| | T-600 AND THE WALL IS REQUIRED TO BE OF |
| | 3 HOUR FIRE RESISTIVE CONSTRUCTION. |
| | |
| | SHEET LS-1 EGRESS CALCULATIONS.USE FBC |
| | TABLE 1004 NOT SECTION 1024.2.6. |
| | |
| | THE MAXIMUM TRAVEL DISTANCE FOR GROUP A2 |
| | IS 200' NOT 250'.FBC T-1004. |
| | |
| | THE TWO HOUR WALL DESIGN ON SHEET LS-1 |
| | AND A8 CITES U 906.THIS DESIGN |
| | INCORPORATES A 6" PROPRIETARY BLOCK NOT |
| | SHOWN AS BEING USED IN THE STRUCTURAL |
| | OR ARCHITECTURAL PLANS.PLEASE CLARIFY. |
| | |
| | THE PLANS DO NOT SHOW PROVISIONS FOR |
| | OCCUPANT CONTENT SIGNS IN ACCORDANCE |
| | WITH FBC 403.1.2.3. |
| | |
| | LS-1 NOTES 75' AS A PERMITTED COMMON |
| | PATH OF TRAVEL.SEE FBC 1019.1.3. |
| | |
| | THERE IS NO INFORMATION ON THE PLANS FOR |
| | THE DOOR HARDWARE.SEE FBC 1012 AND |
| | 1019.7. |
| | |
| | THERE ARE NO DETAILS OR SPECIFICATIONS |
| | FOR THE BLEACHERS SHOWN THROUGH OUT THE |
| | PLANS. |
| | |
| | SHEET A2.1 CALLS OUT SECTIONS 4/8.2 AND |
| | 5/8.2 AND THERE IS NO SHEET 8.2. |
| | |
| | SECTION A/4.3 TAKEN FROM SHEET A3.1 IS |
| | NOT CONGRUENT. |
| | |
| | SHEET A4.3 DETAIL (3).WHERE IS THIS |
| | USED? |
| | |
| | SHEET A6.3, WALL SECTION (7).SHOW A |
| | CONSTRUCTION DETAIL FOR THE SUSPENDED |
| | GYP BOARD CEILING INCLUDING |
| | CONNECTIONS, SIZES, SPACING, MATERIALS |
| | AND DIMENSIONS.FBC 104.2. |
| | |
| | SHEET S4 MASONRY NOTES #4 AND S3 MASONRY |
| | NOTES #2 DO NOT AGREE. |
| | |
| | SHEET S4 CALLS OUT SSTD 12-97, THE FBC |
| | INVOKES 12-99.SEE FBC 35. |
| | |
| | SHEET FP-1, PLEASE NOTE THE CODE |
| | EDITIONS USED, IE NFPA 13-99. |