| Date |
Text |
| 2003-07-05 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 03060449 |
| | ADD: 622 N FLAGLER DR |
| | CONT: PLAN REVIEW |
| | CONTACT: COMMUNITIES FINANCE CORP |
| | TEL: (561)630-4284 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | ACTION : DENIED |
| | |
| | 1) CITY CODE: 94-378(1) ALL NEW MARINAS |
| | SHALL HAVE WRITTEN APPROVAL FROM THE |
| | U.S. ARMY CORP OF ENGINEERS, STATE DERT. |
| | OFENVIROMENTAL REGULATIONS,STATE DEPART- |
| | MENT OF NATURAL RESOURCES, BOARD OF |
| | TRUSTEES OF THE INTERNAL IMPROVEMENT |
| | TRUST FUND, AND THE SOUTH FLORIDA WATER |
| | MANAGEMENT DISTRICT. |
| | |
| | 2) PROJECT LOCATED IN A FLOOD ZONE A5 |
| | BASE FLOOD ELEVATION 7'-0", CITY FLOOD |
| | ZONE REQUIREMENT OF 7'-6" FINISH FLOOR, |
| | THE QUESTION TO DETERMINED IF THIS IS IN |
| | A FLOODWAY WITH MORE RESTRICTIVE REQUIRE |
| | MENTS. |
| | |
| | 3) 1015.1 GUARDRAILS: GUARDRAILS ARE |
| | REQUIRED ON THE DOCKS WITH THE EXCEPTION |
| | #1, NOT ON THE LOADING SIDE OF DOCK. |
| | |
| | 4)1015.2 HEIGHT. GUARDRAILS SHALL |
| | FORM A VERTICAL PROTECTIVE BARRIER NOT |
| | LESS THAN 42" HIGH. |
| | 1015.3 OPENINGS. OPEN GUARDRAILS |
| | SHALL HAVE INTERMEDIATE RAILS OR ORNA- |
| | MENTAL PATTERNS SUCH AS A 4" DIAMETER |
| | SPHERE CAN NOT PASS THROUGH. A BOTTOM |
| | RAIL OR CURB SHALL BE PROVIDED THAT WILL |
| | REJECT THE PASSAGE OF 2" DIAMETER |
| | SPHERE. |
| | |
| | 5) FAIR HOUSING ACT, COMMON AREAS: WHEEL |
| | CHAIR ACCESSIBLITY WITH WOOD LAY IN SEC- |
| | TION, IS THERE SPACES BETWEEN PLANKS NOT |
| | ALLOWING WHEELCHAIR ACCESSIBILITY? |
| | |
| | LOOK FOR COMMENTS BY THE OTHER PLAN |
| | REVIEW DISCIPLINES THAT MAY BE WRITTEN |
| | ON THE APPLICATION, PLANS, OR ATTACHED |
| | SEPARATELY. WHEN RESUBMITTING PLANS |
| | PLEASE CLEARLY INDICATE THE REVISION AND |
| | REMOVE AND REPLACE ANY PAGES AS NECESS- |
| | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH |
| | THE PLANS WHEN RESUBMITTING PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN |
| | BE FOUND, WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | JIM WITMER |
| | BUILDING PLAN REVIEW |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |