 REFERENCE: FBC-2001 PLUMBING
  
 1) SHT A-2 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS. TUB & SHOWER
 NOT VENTED PROPERLY. (TABLE 906.1)
 ISLAND VENT OR AIR ADMITTENCE VALVE REQ-
 UIRED FOR SALAD SINK. TUB & SHOWER SHALL
 NOT DRAIN INTO A HORIZONTAL TEE. (TABLE
 706.3). LAVS SHALL NOT BE DRAINED TO A
 CROSS FITTING. (THEY ARE NOT BACK TO
 BACK). SEE RED LINE CHANGES ON PLANS.
 PLEASE MAKE CORRECTIONS AND RESUBMIT
 PLANS FOR REVIEW.
  