Plan Review Notes
Plan Review Notes For Permit 03052140
Permit Number 03052140
Review Stop B
Sequence Number 2
Notes
Date Text
2003-08-18 00:00:00******CORRECTIONS******
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)ADDITIONAL FEES DUE; $705.57.
  
 3.)PROVIDE THE RECEIPT FOR THE IMPACT
 FEES.
  
 4.)SEE PREVIOUS LIST #11; THE CATALOG
 REQUIRES 20 NAILS; PLAN STILL SHOWS 16
 (A6 AND A7).
  
 5.)SEE PREVIOUS LIST #13; REFER TO
 FBC705.3 AND FBC2305.2.2.THE
 DRAFTSTOPPING SHOWN DOES NOT DIVIDE THE
 FLOOR/CEILING ASSEMBLY INTO AREAS LESS
 THAN 500 SF.
  
 6.)ROOF ON THE TYPICAL WALL SECTION
 (A8) NOW SHOWS TILE ON 15# PAPER.IS
 THIS CORRECT?
  
 7.)REFER TO PREVIOUS LIST, #16.THE
 BUCK ATTACHMENTS ARE STILL NOT ON THE
 PLAN.PLEASE PROVIDE.
  
 8.)TYPICAL WALL SECTION SHOWS SPRAY
 FOAM INSULATION ON THE TOP CHORD OF THE
 TRUSS; INSULATION WHICH WAS PREVIOUSLY
 SHOWN ON THE BOTTOM CHORD IS NO LONGER
 ON THE DETAIL.FBC13-604.1.ABC.1,
 PRESCRIPTIVE REQUIREMENTS FOR METHOD A,
 REQUIRES R19 INSULATION ON THE CEILING.
  
 9.)PROVIDE FIREBLOCK AT STAIRS,
 FBC2305.1.4(3).
  
 10.) PROVIDE THE TEST REPORT FOR THE
 METAL GLAZED DOORS.ADDITIONAL
 INFORMATION IS REFERRED TO ON THE
 REPORT AS BEING AVAILABLE ON THEIR
 WEBSITE.
  
 11.) THE PLAN SHOWS A 24 EGRESS WINDOW.
 IF YOU ARE INSTALLING A 25 SINGLE HUNG,
 CHANGE THE PLAN TO REFLECT THIS TO
 COMPLY WITH FBC1005.4.
  
 12.) SEE PREVIOUS LIST #19.I AM STILL
 UNCLEAR AS TO WHERE THE IMPACT CASEMENT
 WINDOW IS TO BE INSTALLED.THE WINDOW
 CHANGES MADE WERE FOR FIXED WINDOWS.
 PRODUCT APPROVAL IS FOR CASEMENT IMPACT.
 THERE AREN'T ANY CASEMENT WINDOWS SHOWN
 ON THE PLAN.