| 2003-06-19 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 03051851 |
| | ADD: 8853 S. SAN ANDROS |
| | CONT: SIERRA CONST |
| | TEL: (561)616-9686 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | 1) PROVIDE NOC RECORDED WITH THE CLERK |
| | OF COURT BEFORE A PERMIT CAN BE ISSUED. |
| | |
| | 2) FL BLD CODE 1804.2.2 QUESTIONABLE |
| | SOILS, WHERE THE BEARING CAPACITY IS |
| | NOT DEFINETLY KNOWN OR IS IN QUESTION. |
| | THE TESING REPORT IS FOR ANDROS ISLES |
| | PARCEL "E2" PLAT1.THE PARCEL IN QUESTION |
| | IS "E2" PLAT2. |
| | |
| | 3) TABLE 600 ISSUE, GLASS BLOCK, PROVIDE |
| | DOCUMENTATION FOR 1 HR RATING, 0-3' FROM |
| | THE PROPERTY LINE. THIS IS NOT CONSIDER- |
| | ED OPENING BUT WALL 1HR RATING. |
| | |
| | 4) PLANS INDICATE THEUSE OF STORM |
| | SHUTTRS FOR WINDOWS AND SIDELITES BUT |
| | NO STORM SHUTTER INFORMATION ATTACHED. |
| | MISSING PRODUCT APPROVAL, KEY PLAN |
| | AND INSTALLATION SCHEDULE, SEE ATTACH- |
| | MENT FOR SAMPLE. |
| | |
| | 4) 1606.1.7 REQUIRED WIND DESIGN |
| | INFORMATION, MISSING THE INTERNAL |
| | PRESSURE COEFFICIENT. WITHOUT THIS IT |
| | IS ONLY ASSUMED THAT IT IS A CLOSED |
| | BUILDING. |
| | CLOSED BUILDING+-.18 |
| | PARTIAL ENCLOSED +-.55 |
| | OPEN +-.0 |
| | |
| | LOOK FOR COMMENTS BY THE OTHER PLAN |
| | REVIEW DISCIPLINES THAT MAY BE WRITTEN |
| | ON THE APPLICATION, PLANS, OR ATTACHED |
| | SEPARATELY. WHEN RESUBMITTING PLANS |
| | PLEASE CLEARLY INDICATE THE REVISION AND |
| | REMOVE AND REPLACE ANY PAGES AS NECESS- |
| | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH |
| | THE PLANS WHEN RESUBMITTING PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN |
| | BE FOUND, WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | JIM WITMER |
| | BUILDING PLAN REVIEW |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |