| Plan Review Notes For Permit 03051815 |
| Permit Number |
03051815 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2003-07-01 00:00:00 | | | | *** ISSUED PERMIT*** | | | -PLAN REVIEW HISTORY- | | | | | | PERMIT# 03051815 | | | ADDRESS: 8791 S SAN ANDROS | | | CONT: SIERRA | | | TELL # (716)236-5312 | | | | | | THE ATTACHED COMMENTS ARE PART OF THE | | | PERMIT AND PLAN REVIEW PACKAGE AND ARE | | | NOT TO BE REMOVED FROM THE ISSUED SET OF | | | PLANS.104.2.1.2 ADMINISTRATIVE CODE. | | | | | | ******PROVISO****** | | | | | | 1) PROVIDE NEW PRODUCT APPROVAL AND | | | REVISE PLANS FOR THE FRONT ENTRY DOOR | | | BEFORE BUCK INSPECTION, TO COMPLY WITH: | | | R-3 EGRESS DOOR/ 32" CLEAR: | | | 1003.2.1. THE WIDTH OF THE MEANS OF | | | EGRESS SHALL BE DETERMINED FROM THE | | | OCCUPANTS SERVED IN ACCORDANCE WITH | | | TABLE 1004.R-3 MINIMUM CLEAR OPENING OF | | | EXIT DOOR IS 32". 1012.1.1 EGRESS DOORS | | | USED IN THE EXIT ACCESS SHALL PROVIDE A | | | CLEAR OPENING OF NOT LESS THAN 32" WIDE. | | | 1012.1.7 REQUIRED EXIT DOORS SHALL BE | | | OPENABLE FROM THE INSIDE WITHOUT THE USE | | | OF A KEY OR TOOL, OR SPECIAL KNOWEDGE OR | | | EFFORT. MANUALLY OPERATED FLUSH BOLTS OR | | | SURFACE BOLTS ARE PROHIBITED. ALL HARD- | | | WARE MUST BE DIRECT ACTING REQUIRING NO | | | MORE THAN ONE OPERATION. |
|