| 2003-07-10 00:00:00 | ********BUILDING PROVISO******* | | | PERMIT: 03051786 | | | ADD: 2415 CURLEY CUT | | | CONT: SIERRA | | | TEL: (561)616-9686 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1) THE DESIGNER OF RECORD TO PROVIDE THE | | | CORRECTED WIND PRESSURES (FOR "B" ZONE) | | | BEFORE WINDOW & DOOR BUCK INSPECTION. | | | | | | 2) CORRECT A/C SQ FT AREA FOR ENERGY | | | EFFICIENCY CODE ( SAME AS PLANS) | | | | | | 3) STORM SHUTTERS: | | | A) PROVIDE KEY PLAN TO CORRELATE TO THE | | | SHUTTER SCHEDULE. | | | B) BOTTOM FASTENER CAULK-IN, THE VALUE | | | TAKEN IS FOR CONCRETE, NOT CEMENT BLOCK! | | | THIS FASTENER MAY NOT BE USED IN BLOCK, | | | OR IF THIS IS USED IN FILLED CELL, THE | | | CAULK-IN MUST BE IN 2500 PSI CONCRETE | | | (FILLED CELL). OTHER ALTERNATIVE IS A | | | DIFFERENT FASTENER FOR BLOCK. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|