| Date |
Text |
| 2003-06-20 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 03051780 |
| | ADD: 2405 CURLEY CUT |
| | CONT: SIERRA CONSTRUCTION |
| | TEL: (561)616-9686 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | ACTION: DENIED |
| | |
| | 1) FL BLD CODE 1804.2.2 QUESTIONABLE |
| | SOILS, WHERE THE BEARING CAPACITY IS |
| | NOT DEFINETLY KNOWN OR IS IN QUESTION. |
| | REPORT SUBMITTED IS FOR ANDROS ISLES |
| | PARCEL "E2" PLAT 1 NOT PLAT2. |
| | |
| | 2) TABLE 600 ISSUE GLASS BLOCK, PROVIDE |
| | DOCUMENTATION FOR 1 HR. RATING, 0-3' |
| | FROM THE PROPERTY LINE ALLOWS FOR ZERO |
| | OPENINGS IN WALL SO DOCUMENTATION IS FOR |
| | 1 HR NOT 3/4HR FOR OPENINGS. |
| | |
| | 3) PLANS INDICATE THE USE OF STORM |
| | SHUTTERS FOR WINDOWS AND SIDELITES BUTNO |
| | FL BLD CODE 2001 SECTION 103.6, |
| | 1606.1.4, 1707.4 & 3401.7.2.4. |
| | PROCEDURES: 1(B) A COMPLETE INSTALLATION |
| | SCHEDULE SUMMARIZING & IDENTIFYING |
| | OPENING SIZES, STORY HEIGHTS, UNIT MARK |
| | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM |
| | BAR REINFORCING REQUIREMENTS, WALL PRES- |
| | SURE ZONES, SLAT TYPES, ETC., SHALL BE |
| | SUBMITTED AT TIME OF PERMIT APPLICATION |
| | TO FACILITATE PLAN REVIEW AND PERMIT |
| | ISSUANCE.SEE SAMPLE SCHEDULE. |
| | |
| | 4) 1606.1.7 REQUIRED WIND INFORMATION, |
| | MISSING THE INTERNAL PRESSURE COEFFI- |
| | CIENT. WITHOUT THIS IT IS ONLY ASSUMED ? |
| | CLOSED BUILDING+-.18 |
| | PARTIAL +-.55 |
| | OPEN +-.0 |
| | |
| | LOOK FOR COMMENTS BY THE OTHER PLAN |
| | REVIEW DISCIPLINES THAT MAY BE WRITTEN |
| | ON THE APPLICATION, PLANS, OR ATTACHED |
| | SEPARATELY. WHEN RESUBMITTING PLANS |
| | PLEASE CLEARLY INDICATE THE REVISION AND |
| | REMOVE AND REPLACE ANY PAGES AS NECESS- |
| | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH |
| | THE PLANS WHEN RESUBMITTING PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN |
| | BE FOUND, WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | JIM WITMER |
| | BUILDING PLAN REVIEW |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |