| 2003-06-10 00:00:00 | ******CORRECTIONS******* |
| | |
| | SAMANTHA THYNG, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | 1.)ARCHITECT'S SEAL IS REQUIRED TO |
| | BE DATED. |
| | |
| | 2.)SEPARATE PERMITS ARE REQUIRED FOR |
| | ROOF, MECHANICAL, PLUMBING, AND |
| | ELECTRIC. |
| | |
| | 3.)ENERGY CALCS REQUIRED FBC 13-101.2. |
| | |
| | 4.)A NOTICE OF COMMENCEMENT IS |
| | REQUIRED TO BE FILED WITH THE CLERK OF |
| | COURTS BEFORE A PERMIT CAN BE ISSUED. |
| | |
| | 5.)IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY.THE PLANS MUST BE STAMPED |
| | AND THE ORIGINAL RECEIPT ATTACHED TO |
| | THE APPLICATION.233-5025 |
| | |
| | 6.)ADDITIONAL FEES REQUIRED; $2.16. |
| | |
| | 7.)FOR WINDOWS BEING REPLACED IN THE |
| | EXISTING HOUSE, SHOW THE SIZE AND |
| | TYPE.BEDROOMS ARE REQUIRED TO HAVE |
| | EMERGENCY EGRESS FBC 1005.4. |
| | |
| | 8.)IMPACT PROTECTION REQUIRED FOR |
| | WINDOWS, FBC 1606.1.4.THIS INCLUDES |
| | THE REPLACEMENT WINDOWS. |
| | |
| | 9.)SHOW THE 1 1/2" WATERSTOP, 4" |
| | ABOVE GRADE MIN, AND 12" MIN BELOW |
| | GRADE (FOUNDATION) ON THE WALL SECTIONS. |
| | IT IS SHOWN GRAPHICALLY, BUT PLEASE |
| | GIVE DIMENSIONS. |
| | |
| | 10.)FIRESTOP REQUIRED, FBC 705.3. |
| | |
| | 11.)SUBMIT TWO COPIES OF PRODUCT |
| | APPROVALS: |
| | WINDOWS (EACH TYPE TO BE INSTALLED) |
| | IMPACT PROTECTION |
| | SHINGLES (MAY BE SUBMITTED W/ROOF |
| | PERMIT APPLICATION) |
| | NEW DOOR AT LIVING ROOM |
| | MULLIONS |
| | FRENCH DOORS |
| | IF PRODUCT APPROVALS ARE NOT SUBMITTED |
| | WITH THE OTHER CORRECTIONS, A PERMIT |
| | MUST BE APPLIED FOR SEPARATELY FOR |
| | THESE ITEMS. |
| | |
| | 12.)IF HURRICANE SHUTTERS ARE TO BE |
| | INSTALLED, PROVIDE A HURRICANE SHUTTER |
| | SCHEDULE (SEE ATTACHED). |